Related Experiment Video
Updated: Aug 8, 2026

Use of a Low-flow Digital Anesthesia System for Mice and Rats
Published on: September 7, 2016
Closed circuit anaesthesia in ventilated patients using the Komesaroff vaporizer within the circle
J S Bewley1, R J Eltringham, P Sanderson
1Department of Anaesthesia, Gloucester Royal Hospital, U.K.
Abstract:
A study was undertaken to assess the performance of the Komesaroff vaporizer, placed within the circuit, in ventilated patients during maintenance of closed circuit anaesthesia with halothane or isoflurane. Following intravenous induction, anaesthesia was maintained by inhalation. This was achieved using a conventional vaporizer outside the circle for the first 10 minutes to manage the fast uptake phase. The fresh gas flow was then reduced to the basal oxygen requirement with the Komesaroff vaporizer within the circle maintaining inhalational anaesthesia. Complete isolation of the circuit was achieved by returning all anaesthetic gases to the circuit following analysis and using a bag-in-bottle ventilator. The Komesaroff vaporizer dial was positioned at between the first and second division and end-tidal volatile anaesthetic agent levels were measured. This study demonstrated that at dial positions 1 or 1.5 with either agent, the end-tidal volatile concentration plateaued at clinically acceptable levels. The Komesaroff vaporizer can therefore be used safely in ventilated patients to maintain closed circuit anaesthesia provided clinical observation and monitoring are meticulous.
More Related Videos
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia
Inhalational Anesthetics: Overview
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Tracheostomy Suctioning II: Procedure