Determinants of the bronchial response to high molecular weight occupational agents in a dry aerosol form
Related Experiment Video
Updated: Oct 27, 2026

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
Published on: May 15, 2013
B Nguyen1, K Weytjens, Y Cloutier
1Dept of Chest Medicine, Hôpital du Sacré-Couer, Montreal, Canada.
Abstract:
In occupational challenge tests with isocyanate vapours, bronchial responsiveness is determined by the total dose rather than the concentration or duration of exposure. Whether the same applies for high molecular weight (HMW) agents in powder form is unknown. The aim of this study was to determine whether the total dose of HMW agents in powder form is responsible for the immediate reaction documented in specific challenge tests. Included in the study were nine subjects (seven males and two females) with a diagnosis of occupational asthma proved by specific challenge tests carried out on a preliminary visit. Two challenge tests (using a closed-circuit exposure chamber) were performed at an interval of 2 weeks; the concentrations administered in a random order on these two visits were half and double the one that had caused a 20% fall in forced expiratory volume in one second (FEV1) on a preliminary visit. The duration of exposure was adjusted until a significant fall in FEV1 (target of 20%) occurred. The two concentrations obtained were significantly different, by 2.07+/-0.36-fold (SD). The observed durations of exposure leading to a 20% fall in FEV1 on the two visits also differed significantly by 0.46+/-0.32-fold. Consequently, the cumulative efficient doses were not significantly different between the two visits: 12+/-5.4 and 9+/-5 mg x mL(-1) x min(-1), respectively. The corresponding cumulative dose ratio was 0.96+/-0.61. The expected duration of exposure (10.8+/-24 min) was not significantly different from the observed duration (5.4+/-9 min). The mean and 95% confidence interval for the difference in concentration between the two visits was 1.83-fold (1.48-2.21). In conclusion, the total dose rather than the concentration or duration of exposure per se determines bronchial responsiveness to high molecular weight agents in powder form.
More Related Videos
08:44Identification and Characterization of Immunogenic RNA Species in HDM Allergens that Modulate Eosinophilic Lung Inflammation
Published on: May 30, 2020
09:58A Reversible, Non-invasive Method for Airway Resistance Measurements and Bronchoalveolar Lavage Fluid Sampling in Mice
Published on: April 13, 2010
Related Concept Videos
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features
Asthma I: Introduction
Asthma-I: Introduction
Chronic Obstructive Pulmonary Disease I: Introduction
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation