Statement Of Problem:
Soft tissue denture liners frequently require replacement that necessitates complete removal from the denture base. A high speed lathe located in a "clean laboratory" is often used to facilitate removal of these materials, but it is unclear whether routine disinfection procedures reduce bacterial contamination sufficiently to prevent contamination of the laboratory.
Purpose:
The first phase of this study evaluated the effectiveness of 3-minute chlorine dioxide spray and immersion disinfection procedures on 2 denture liners (Coe Soft and Coe Comfort) and stainless steel specimens used as controls. The second phase evaluated the effectiveness of spray disinfection at time intervals of 1, 3, and 10 minutes.
Material And Methods:
Specimens made of soft denture liners attached to acrylic resin bases (10 per group) were contaminated with Escherichia coli, Staphylococcus aureus, and Candida albicans. Colony-forming units were counted after different disinfection techniques were applied. Kruskal-Wallis 1-way analysis of variance on ranks and an all pairwise multiple comparison procedures (Dunn's method) were used to test for significant differences among test groups at the P <.05 level of significance.
Results:
Chlorine dioxide was effective against nonporous stainless steel specimens but was inadequate for denture liners at the recommended 3-minute time of disinfection. The immersion technique was more effective than the spray technique, but the difference was not significant. Increasing the time of disinfection did not significantly reduce the numbers of microorganisms.
Conclusion:
Coe Soft and Coe Comfort denture liners should be removed before entering the laboratory. These materials contain sufficient viable bacteria after routine disinfection procedures to cause contamination of the "clean laboratory."
More Related Videos
06:022-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
07:07Controlled-release of Chlorine Dioxide in a Perforated Packaging System to Extend the Storage Life and Improve the Safety of Grape Tomatoes
Published on: April 7, 2017
Related Concept Videos
Electrolysis
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Chemical Agents for Microbial Control
Antimicrobial Effectiveness