Estimation of cardiac function from computer analysis of the arterial pressure waveform
M Guarini1, J Urzúa, A Cipriano
1Department of Electrical Engineering, Catholic University of Chile, Chile. mguarini@ing.puc.cl
Abstract:
This paper presents a method for estimating parameters of a cardiovascular model, including the left-ventricular function, using the sequential quadratic programming (SQP) and the least minimum square (LMS) algorithms. In a first stage, a radial arterial-pressure waveform with corresponding cardiac output are used to automatically seek the set of parameters of the diastolic model. Computer simulation of the model using these parameters generate a pressure waveform and a cardiac output very close to those used for the estimation. In a second stage, the estimated arterial load parameters are used to select the best left-ventricular model function, from four different possibilities, and to estimate its optimum parameter values. The method has been tested numerically and applied to real cases, using data obtained from cardiovascular patients. It has also been subjected to preliminary validation using data obtained from laboratory dogs, in which cardiovascular function was artificially altered.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical indicator...