Related Experiment Video
Updated: Aug 19, 2026

Use of a Low-flow Digital Anesthesia System for Mice and Rats
Published on: September 7, 2016
Variations in the composition of spinal anesthetic solutions: the effects of drug addition order and preparation
1Department of Anesthesia and Critical Care, Massachusetts General Hospital, Harvard Medical School, Boston 02114, USA.
Unlabelled:
Adjuvants such as opioids or epinephrine are commonly added in small volumes to multicomponent spinal anesthetic solutions. In this study, we tested the hypothesis that final adjuvant concentrations vary depending on the devices and techniques used to prepare the anesthetic solution. We compared two aspiration devices, the filter needle and the filter straw, in a laboratory study. Two techniques for drawing up and estimating adjuvant volumes were assessed, as was variation in the composition of a model spinal anesthetic solution resulting from intra- and interindividual variability. A model hyperbaric anesthetic solution consisting of tetracaine, dextrose, and methylene blue (MB) as a small-volume tracer solution was studied. The components were drawn up into a syringe through one of two commercially supplied aspiration devices, a filter straw or a filter needle. The effect of the order of aspiration of the components into the syringe was measured by determining the MB concentration in the final solution by optical absorbance. Ten experienced anesthesiologists then prepared samples of the test solution using one of two different techniques to estimate tracer volume in the aspiration syringe. In comparison studies, the MB tracer was added to the hyperbaric solution with a tuberculin syringe. The order of aspiration of the solution components had a large effect on the final concentration of the MB tracer in the ultimate mixture. Variation in the MB concentration was on the order of four- to fivefold. Effects were larger for the filter straw compared with the filter needle. A comparison of 10 anesthesiologists revealed large intra- and interindividual variations in the final composition of the model anesthetic solution. The concentration of tracer added to the mixture with a tuberculin syringe approximated the planned yield. We conclude that the devices and techniques used to prepare mixtures of drugs for delivery to the cerebrospinal fluid may influence the concentrations of drugs in the anesthetic and, thus, the dose supplied to the patient receiving spinal anesthesia. Variation in clinical effects of spinal anesthetics may be attributable, in part, to variation in the composition of the anesthetic.
Implications:
This laboratory study demonstrates the potential for large variation in the composition of spinal anesthetic mixtures.
Related Concept Videos
Local Anesthetics: Pharmacokinetics
Local Anesthetics: Adverse Effects
Once absorbed into the systemic circulation, local anesthetics can affect the organs that depend on the functioning of sodium...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Parenteral Anesthetics: Overview
Inhalational Anesthetics: Overview

