Related Experiment Video
Updated: Aug 15, 2026

Preparation and Pathogen Inactivation of Double Dose Buffy Coat Platelet Products using the INTERCEPT Blood System
Published on: December 7, 2012
Platelets stored in a new-generation container differences between plasma and platelet additive solution II
J de Wildt-Eggen1, J G Schrijver, W M Smid
1Red Cross Bloodbank IJssellanden, Zwolle, The Netherlands.
Background And Objectives:
In order to preserve platelet concentrates (PCs) with high yields, a new polyolefin platelet storage container (PL 2410, 1.3L, Baxter, La Châtre, France) with increased gas permeability in combination with a larger surface area has been developed. The storage capacity was studied with platelets in plasma and platelets additive solution.
Materials And Methods:
Platelet concentrate pools (PCs) of different yields suspended in either plasma (PCs-PL; n = 30) or PAS II (PCs-PAS; n = 37) were prepared. For preparation of PCs with a low, intermediate and high number of platelets 3, 5 and 6 buffy coat (BCs) were pooled with different volumes of plasma and 5 and 6 BCs were pooled with different volumes of PAS II, in order to obtain PCs of equal volumes comparable with routine conditions. All PCs were stored on a flatbed shaker at 22+/-2 degrees C and evaluated on days 1, 2, 5 and 7 by determining platelet and white cell counts, pH (37 degrees C), pO2, pCO2 and swirling score.
Results:
Platelet yields ranged from 1.5 up to 5.5 x 10(11) platelets/U. On day 7 all PCs-PL (n = 4) with platelet yields above 4.5 x 10(11)/U had a pH value below 6.8 (range 5.91-6.79). While 7 of 8 PCs-PAS units with platelet yields above 4. 0 x 10(11)/U showed a pH value below 6.8 (range 6.31-6.70).
Conclusion:
During 7 days of storage in a new 1.3-liter platelet container, the pH was maintained above 6.8 in PCs in plasma with a yield between 1.5- and 4.5 x 10(11)/U; when PAS II was used, the maximum platelet yield allowed for comparable pH maintenance was somewhat lower (4.0 x 10(11)/U).
More Related Videos
09:13Turbidimetry on Human Washed Platelets: The Effect of the Pannexin1-inhibitor Brilliant Blue FCF on Collagen-induced Aggregation
Published on: April 6, 2017
05:49Procoagulant Platelet Characterization by Measuring Phosphatidylserine Exposure and Microvesicle Release from Human Purified Platelets
Published on: November 29, 2024
Related Concept Videos
Structure and Function of Platelets
Platelets are continually replenished, circulating in the bloodstream for 9-12 days before being removed by phagocytes, primarily in the spleen. A microliter of circulating blood contains between 150,000 and 450,000 platelets, with...
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...