Related Experiment Video
Updated: Aug 14, 2026

Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
Published on: March 3, 2010
Measurement of tissue oxygen with a fluorescent probe
Abstract:
Evidence is presented that pyrenebutyric acid is nontoxic at the concentrations required for the measurement of fluorescence quenching by physiological concentrations of oxygen. It appears that this molecule can be used to measure tissue oxygen since it does not interfere with oxygen consumption. Equally, tissue components do not interfere with the quenching of fluorescence to such an extent as to invalidate the method. The spatial resolution of the technique is limited by some tissue geometrical factors which do not, however, appear to be great enough to prevent its use to measure intercapillary oxygen gradients.