Related Experiment Video
Updated: Aug 4, 2026

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
A change in treatment process with a modern record and verify system
E E Klein1, R E Drzymala, R Williams
1Radiation Oncology Center, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA.
A record and verify (R&V) system like Varis improves radiation therapy accuracy by reducing errors, despite initial workload increases. Integrated systems enhance efficiency and patient safety.
Area of Science:
- Radiation Oncology
- Medical Physics
- Health Informatics
Background:
- Advancements in radiation therapy, including multileaf collimators (MLC) and dynamic wedges (DW), increase therapist responsibility.
- Three-dimensional treatment planning (3DTP) necessitates comprehensive record and verify (R&V) systems for managing increased treatment complexity and efficiency.
Purpose of the Study:
- To evaluate the reliability, usability, efficiency, and integration of a commercial Varis record and verify (R&V) system.
- Assess the impact of the Varis R&V system on treatment processes and error rates in a clinical setting.
Main Methods:
- The Varis system's features, including MLC/DW integration and auto-setup capabilities, were analyzed.
- Evaluation focused on treatment time, error rates, and workload changes, considering how duties were redistributed and processes adapted.
Main Results:
- While initial data entry workload increased for dosimetrists and physics staff, notable events decreased tenfold.
- Therapists using Varis efficiently experienced slight decreases in treatment times due to MLC integration and auto-setup.
- Some therapists faced efficiency challenges due to unfamiliarity, and errors persisted due to reliance on incorrect electronic data.
Conclusions:
- The Varis R&V system significantly impacted clinic processes, reducing errors and misconceptions through rigorous data checking and field scheduling.
- An integrated R&V system allows for more accurate and efficient operation of dual-energy machines with fewer therapists.
- Future Varis releases are expected to further enhance efficiency and accuracy in radiation therapy delivery.
More Related Videos
Related Concept Videos
Data Reporting and Recording
Purpose of Health Records I
Here's a breakdown of how health records serve these purposes:
Purpose of Health Records II
Methods of Documentation VI: Case Management Model
For example, a patient with a chronic illness...
Methods of Documentation VII: EMR
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security: