Related Experiment Video
Updated: Aug 11, 2026

Fabrication and Implantation of Miniature Dual-element Strain Gages for Measuring In Vivo Gastrointestinal Contractions in Rodents.
Published on: September 18, 2014
Gastric versus duodenal feeding and gastric tonometric measurements
B Levy1, P F Perrigault, P Gawalkiewicz
1Polyvalent Intensive Care Unit, Central Hospital, Nancy, France. b.levy@chu-nancy.fr
Objective:
To compare the influence of gastric and postpyloric enteral feeding on the gastric tonometric PCO2 gap (tonometric PCO2 - PaCO2).
Design:
A prospective, clinical trial.
Setting:
Two intensive care units in a university hospital.
Patients:
Twenty patients undergoing mechanical ventilation and enteral feeding without catecholamines, sepsis, or sign of hypoxia.
Interventions:
Patients were randomized to receive feeding through the tonometer (gastric group), or through a postpyloric tube (postpyloric group).
Measurements And Main Results:
The patients received tube feeding at a rate of 50 mL/hr during 4 hrs. Baseline measurements included: mean arterial pressure, heart rate, tonometric parameters, arterial gases, and arterial lactate concentration. Except for lactate concentration, these measurements were repeated after 1 and 4 hrs of enteral feeding and 2 hrs after stopping enteral feeding. During the study, arterial pH and PaCO2 did not change. During enteral feeding, the PCO2 gap increased in the gastric group from a mean of 7+/-5 to 17+/-14 (SD) torr (0.9 0.7 to 2.3+/-1.9 kPa) (p< .O01) and did not change in the postpyloric group (5+/-5 to 3+/-1 torr [0.7+/-0.7 to 0.4+/-0.1 kPa]). Two hours after stopping enteral feeding, the PCO2 gap was still increased in the gastric group (15+/-9 vs. 7+/-5 torr [2.0+/-1.2 vs. 0.9+/-0.7 kPa]) (p < .01).
Conclusion:
The results indicate that gastric enteral feeding increased the PCO2 gap. However, postpyloric enteral feeding does not interact with gastric tonometric measurements and should be used when using gastric tonometry in enterally fed patients.
Related Concept Videos
Stomach pH Regulation
The acid-secreting gastric mucosal epithelial cells (parietal cells) lining the stomach lumen maintain the low pH in the lumen. Numerous ion transporters and channels on these parietal...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Enteral Nutrition I: Orogastric and Nasogastric Feeding
Orogastric (OG) and nasogastric (NG) feeding are two standard methods used for enteral nutrition. Enteral nutrition is often preferred over...
Enteral Nutrition II: Nasointestinal and Gastrostomy Feeding
Nasointestinal Feeding
Nasointestinal feeding involves placing a tube through...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...