Pressure monitoring devices. Overlooked source of nosocomial infection
Abstract:
Contaminated pressure monitoring devices recently have been implicated as a source of epidemic organisms in three outbreaks of nosocomial bacteremia, one outbreak of candidemia, and one outbreak of hepatitis. Measures necessary to prevent monitoring-related infections have not always been appreciated or taken. As a minimum, pressure monitoring devices should be sterilized between use with different patients; strict aseptic technique should be employed when setting up and using monitoring systems; and each patient's monitoring tubing, fluid, and monitoring devices should be changed at regular intervals.
Insights
Contaminated pressure monitoring devices can cause serious hospital infections. Sterilization, aseptic techniques, and regular changes of monitoring equipment are crucial to prevent patient harm.
Area of Science:
- Healthcare-associated infections
- Infection control
- Medical device safety
Background:
- Nosocomial infections are a significant concern in healthcare settings.
- Contaminated pressure monitoring devices have been linked to outbreaks of bacteremia, candidemia, and hepatitis.
- Inadequate infection control measures have contributed to these outbreaks.
Purpose of the Study:
- To highlight the role of contaminated pressure monitoring devices in nosocomial infections.
- To emphasize the importance of implementing proper infection control measures.
- To provide recommendations for preventing monitoring-related infections.
Main Methods:
- Review of outbreaks implicating pressure monitoring devices.
- Analysis of infection control practices related to pressure monitoring systems.
- Identification of critical preventive measures.
Main Results:
- Pressure monitoring devices identified as a source of epidemic organisms in multiple outbreaks.
- Nosocomial bacteremia, candidemia, and hepatitis outbreaks linked to device contamination.
- Failure to consistently implement necessary preventive measures.
Conclusions:
- Sterilization of pressure monitoring devices between patients is essential.
- Strict aseptic technique is required for setup and use of monitoring systems.
- Regular replacement of monitoring tubing, fluid, and devices is critical for patient safety.
More Related Videos
09:57A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
06:27Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Related Concept Videos
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies. Common...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...