Related Experiment Video
Updated: Oct 26, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Simultaneous determination of 5-fluorouracil and uracil by high-performance liquid chromatography using four serial
L K House1, J Ramírez, M J Ratain
1Department of Medicine, The University of Chicago, IL 60637, USA.
Abstract:
A sensitive assay was developed for the quantitation of 5-fluorouracil (5-FU) and uracil using liquid-liquid extraction (LLE) and HPLC with UV detection. Analyses were performed with four microBondapak C18 columns connected in series using 20 mM acetic acid with 1% ACN as mobile phase. The calibration curves were linear across the range of 26-1000 ng ml(-1) (0.21-7.8 microM) for 5-FU and 1.0-14.0 microg ml(-1) (0.01-110 microM) for uracil. This assay has been implemented to determine the plasma concentrations for pharmacokinetic studies for 5-FU and uracil in conjunction with clinical trials.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Principles Of Column Chromatography
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...