Related Experiment Video
Updated: Aug 14, 2026

Capsular Serotyping of Streptococcus pneumoniae by Latex Agglutination
Published on: September 25, 2014
Microcapsule agglutination test for the diagnosis of leptospirosis in Thailand
Y Suputtamongkol1, S Sarawish, S Silpasakorn
1Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. siysp@mahidol.ac.th
Abstract:
Sera from 82 cases of leptospirosis (confirmed by micro-agglutination tests or IFAT) and 108 patients with other diseases were investigated using the microcapsule agglutination test (MCAT) for leptospirosis. The overall sensitivity (90.2%), specificity (96.3%), positive predictive value (94.9%), negative predictive value (92.9%), and accuracy of the MCAT (93.7%) were encouraging. MCAT is simple, can be performed by unskilled personnel with minimum laboratory facilities, and produces results in 3 h. MCAT would be a reliable serodiagnostic test for rapidly screening individuals for leptospirosis, in various geographical areas of Thailand.