Related Experiment Video
Updated: Jul 24, 2026

Cardiac Stress Test Induced by Dobutamine and Monitored by Cardiac Catheterization in Mice
Published on: February 10, 2013
Uptake of seven myocardial tracers during increased myocardial blood flow by dobutamine infusion
A F Rosenbaum1, A J McGoron, R W Millard
1Department of Internal Medicine, University of Cincinnati College of Medicine, Ohio, USA.
Rationale And Objectives:
Direct comparison of myocardial perfusion tracers has been made difficult by variability in experimental models, and by a virtual absence of data comparing tracer uptake to myocardial blood flow under conditions of increased myocardial oxygen consumption, similar to what occurs with dynamic exercise.
Methods:
Tracer uptake versus myocardial blood flow was evaluated for thallium-201 (201TI) and six technetium-99m (99mTc) myocardial-imaging agents in 24 open-chest canines with an occluded left-anterior descending coronary artery during dobutamine infusion. Data were fitted to the exponential model y = ax(1 - exp[-PSc/x]), where y is the tissue tracer/g normalized to normal (activity at 1 mL/minute/g) and x is the blood flow measured by the radioactive microsphere method.
Results:
With dobutamine, myocardial tracer uptake was linear across a wide range of ischemic and hyperemic flows for each tracer. Based on the permeability surface area product, 201TI and 99mTc Q3 provided the best tracer estimate of myocardial blood flow (5.30+/-0.86 mL/minute/g, r = 0.91; 5.46+/-0.58 mL/minute/g, r = 0.94, respectively). Correlation coefficient (r) values for other tracers studied were 99mTc Q4 (r =0.93), 99mTc Q12 (r = 0.93), 99mTc sestamibi (r = 0.90), 99mTc tetrofosmin (r = 0.96), and 99mTc-N-Noet (r = 0.82).
Conclusions:
Of the 99mTc tracers examined under conditions of dobutamine-altered myocardial contractility, the myocardial uptake properties of 99mTc Q3 were most similar to those of 201TI.