Related Experiment Videos
The maximum expiratory flow rate and volume dependent respiratory resistance in small airway obstruction
Abstract:
In 8 healthy subjects (group A) and 4 subjects with respiratory symptoms (group B), the lung pressure-volume curve (P-V curve), maximum expiratory flow-volume curve (MEFVC) and respiratory resistance (Rrs) at all vital capacities were measured. To avoid laryngeal artifact on a mouth pressure, an intratracheal catheter was used for measurement of Rrs which was obtained with 3 cycles/sec oscillatory forced pressure. Group B did not show a different elastic recoil from group A. In comparison of the maximum expiratory flow (Vmax) at 80, 70, 60 and 50% of the total lung capacity (TLC). Vmax of group B showed lower values than that of group A. Rrs was almost the same in both groups from 70% TLC upwards, but Rrs of group B was higher than that of group A from 65%TLC downwards. Since the lung elastic recoil pressures (Pst (1)) in the two groups were not different and Rrs's were different significantly only at low lung volumes, the decrease in Vmax of group B was supposed to be due to the increased Rrs which might reflect small airway obstruction.