Related Experiment Video
Updated: Oct 24, 2026

An Experimental and Finite Element Protocol to Investigate the Transport of Neutral and Charged Solutes across Articular Cartilage
Published on: April 23, 2017
Time dependence of iopamidol and iodixanol in arthrography of the knee
R Y Carlier1, P Akeson, G Morvan
1Radiology Department, Hôpital Raymond Poincaré, Garches, France.
Purpose:
The safety and diagnostic efficacy of iodixanol (Visipaque) 270 mg I/ml was compared to that of iopamidol (Iopamiron) 300 mg I/ml in knee arthrography.
Material And Methods:
This trial was a bi-center double-blind trial including 128 patients (iodixanol/iopamidol 64/64 patients). Efficacy was evaluated by blinded grading of the diagnostic quality of the p.a. images taken 0, 12 and 25 min after contrast administration by the examining radiologist and later at a consensus evaluation by two experienced skeletal radiologists. Adverse events were recorded.
Results:
No patient experienced any adverse event. The proportion of better images at both 12 and 25 min after injection was higher in the iodixanol group compared to the iopamidol group both by the examining radiologist and at the consensus evaluation.
Conclusion:
In the knee joint iodixanol is a safe contrast medium. The contrast effect of iodixanol lasted longer than that of iopamidol, which can be important when performing arthrography, especially CT arthrography, where the time between puncture and examination can be prolonged.
Related Concept Videos
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography