Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Sound Waves: Resonance01:14

Sound Waves: Resonance

Resonance is produced depending on the boundary conditions imposed on a wave. Resonance can be produced in a string under tension with symmetrical boundary conditions (i.e., has a node at each end). A node is defined as a fixed point where the string does not move. The symmetrical boundary conditions result in some frequencies resonating and producing standing waves, while other frequencies interfere destructively. Sound waves can resonate in a hollow tube, and the frequencies of the sound...
Resonance in an AC Circuit01:26

Resonance in an AC Circuit

The property of an inductor makes it resist any change in the current passing through it, while the property of a capacitor is to build up the charge across its terminals. Hence, if an inductor and capacitor are connected in series, they have opposite effects on the relative phase between current and voltage. The current through the circuit undergoes forced oscillation at the frequency of the source. The resistance term in an R-L-C circuit acts as a damping term because power is dissipated...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Series Resonance01:17

Series Resonance

The RLC circuit impedance is defined as the ratio of the supply voltage to the circuit current. Resonance in such a circuit occurs when the imaginary part of this impedance equals zero. This specific condition means that the inductive reactance is exactly equal to the capacitive reactance. The frequency at which this happens is known as the resonant frequency. Mathematically, the resonant frequency is inversely proportional to the square root of the product of the inductance (L) and capacitance...
Characteristics of Series Resonant Circuit01:24

Characteristics of Series Resonant Circuit

Series resonance occurs in a circuit containing inductive (L), capacitive (C), and resistive (R) elements connected sequentially. At the resonance frequency, the inductive and capacitive reactances are equal in magnitude but opposite in sign, effectively canceling each other. This causes the circuit's impedance is minimal, primarily determined by the resistance R. The resonant frequency of an RLC circuit is defined as:
Parallel Resonance01:23

Parallel Resonance

The parallel RLC circuit is an arrangement where the resistor (R), inductor (L), and capacitor (C) are all connected to the same nodes and, as a result, share the same voltage across them. The parallel RLC circuit is analyzed in terms of admittance (Y), which reflects the ease with which current can flow. The admittance is given by:

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Antrum Tubæ of Rœderer.

Medical examiner (Philadelphia, Pa.)·2023
Same author

Cholera Infantum: A Paper Read before the Central Wabash Medical Society.

The North-Western medical and surgical journal·2023
Same author

On applicability of laccase as label in the mediated and mediatorless electroimmunoassay: effect of distance on the direct electron transfer between laccase and electrode.

Biosensors & bioelectronics·2001
Same author

Experimental observation of dynamics near the torus-doubling terminal critical point

Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics·2001
Same author

Passive particle transport in three-vortex flow

Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics·2000
Same author

Critical point of tori collision in quasiperiodically forced systems

Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics·2000

Related Experiment Video

Updated: Jul 11, 2026

Resonance Raman Spectroscopy of Extreme Nanowires and Other 1D Systems
07:44

Resonance Raman Spectroscopy of Extreme Nanowires and Other 1D Systems

Published on: April 28, 2016

Reentrant resonant tunneling

Kuznetsov, Savchenko, Raikh

    Physical Review. B, Condensed Matter
    |July 15, 1996
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Recombination Dynamics in Thin-film Photovoltaic Materials via Time-resolved Microwave Conductivity
    11:30

    Recombination Dynamics in Thin-film Photovoltaic Materials via Time-resolved Microwave Conductivity

    Published on: March 6, 2017

    All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics
    11:33

    All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics

    Published on: January 19, 2018

    Related Experiment Videos

    Last Updated: Jul 11, 2026

    Resonance Raman Spectroscopy of Extreme Nanowires and Other 1D Systems
    07:44

    Resonance Raman Spectroscopy of Extreme Nanowires and Other 1D Systems

    Published on: April 28, 2016

    Recombination Dynamics in Thin-film Photovoltaic Materials via Time-resolved Microwave Conductivity
    11:30

    Recombination Dynamics in Thin-film Photovoltaic Materials via Time-resolved Microwave Conductivity

    Published on: March 6, 2017

    All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics
    11:33

    All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics

    Published on: January 19, 2018