Factors affecting intrauterine contraceptive device performance. I. Endometrial cavity length
American Journal of Obstetrics and Gynecology
|December 15, 1976
Abstract:
The relationship of endometrial cavity length to intrauterine contraceptive device (IUD) performance was evaluated in 319 patients wearing three types of devices. The rate of events, defined as pregnancy, expulsion, or medical removal, increased significantly when the length of the IUD was equal to, exceeded, or was shorter by two or more centimeters than the length of the endometrial cavity. Total uterine length was found to be a less accurate prognostic indicator of IUD performance than endometrial cavity length alone.
Keywords:
Acceptor CharacteristicsBiologyClinical ResearchContraceptionContraception ContinuationContraception FailureContraception TerminationContraceptive MethodsContraceptive UsageDemographic FactorsEvaluationFamily PlanningFertilityFertility MeasurementsGenitaliaGenitalia, FemaleInsertionIudIud, Copper ReleasingIud, UnmedicatedParityPhysiologyPopulationPopulation DynamicsResearch MethodologyRetentionTreatmentUrogenital SystemUse-effectivenessUterus