Search research articles
Contact Us
Filters
Showing results (1-10 of 23) with videos related to
Page
of 3
Sort By:
Journal of the Mechanical Behavior of Biomedical Materials
|
January 26, 2021
Taper junctions in modular hip joint replacements: What affects their stability?
Ulrike Mueller, Therese Bormann, Stefan Schroeder, et al.
Journal of the Mechanical Behavior of Biomedical Materials
|
December 23, 2023
Is taper corrosion in modular revision hip stem junctions associated with patient or implant specific factors? A retrieval analysis
Therese Bormann, J Philippe Kretzer, Sebastian Jaeger, et al.
Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society
|
October 3, 2025
Corrosion in Modular Revision Hip Stem Tapers - A Retrieval Analysis
Therese Bormann, Haolan Yan, Sebastian Jaeger, et al.
Scientific Reports
|
April 6, 2025
Taper wear in total joint arthroplasty can be reliably assessed with various coordinate measuring systems
Therese Bormann, Ulrike Mueller, Robert Sonntag, et al.
Der Orthopade
|
July 13, 2021
[Typing and particle analysis of squeaking hip endoprostheses : First histopathological analysis to examine the squeaking pathogenesis of ceramic-on-ceramic bearings]
Stephanie Eiden, Therese Bormann, Jan Philippe Kretzer, et al.
Journal of the Mechanical Behavior of Biomedical Materials
|
June 10, 2022
Taper corrosion in total hip arthroplasty - How to assess and which design features are crucial?
Ulrike Mueller, Therese Bormann, Stefan Schroeder, et al.
Bone & Joint Research
|
June 17, 2026
Subluxation-induced liner adhesion and the effect of impaction to prevent liner dislocation in ceramic hip arthroplasty
Maximilian Uhler, Mareike Schonhoff, Sebastian Jäger, et al.
Orthopadie (Heidelberg, Germany)
|
June 4, 2024
[Tribology in arthroplasty : Friction and wear, a key to a long lifetime]
Joachim Döring, Therese Bormann, Adrian Buchholz, et al.
Journal of the Mechanical Behavior of Biomedical Materials
|
February 12, 2022
Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty
Phuong Thao Mai, Therese Bormann, Ulrike Müller, et al.
Materials (Basel, Switzerland)
|
November 7, 2020
Short-Term Heat Treatment of Ti6Al4V ELI as Implant Material
Phuong Thao Mai, Therese Bormann, Robert Sonntag, et al.
Page
of 3
Search research articles
Search
Showing results (1-10 of 23) with videos related to
Sort By:
Page
of 3
Journal of the Mechanical Behavior of Biomedical Materials
|
January 26, 2021
Taper junctions in modular hip joint replacements: What affects their stability?
Ulrike Mueller, Therese Bormann, Stefan Schroeder, et al.
Journal of the Mechanical Behavior of Biomedical Materials
|
December 23, 2023
Is taper corrosion in modular revision hip stem junctions associated with patient or implant specific factors? A retrieval analysis
Therese Bormann, J Philippe Kretzer, Sebastian Jaeger, et al.
Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society
|
October 3, 2025
Corrosion in Modular Revision Hip Stem Tapers - A Retrieval Analysis
Therese Bormann, Haolan Yan, Sebastian Jaeger, et al.
Scientific Reports
|
April 6, 2025
Taper wear in total joint arthroplasty can be reliably assessed with various coordinate measuring systems
Therese Bormann, Ulrike Mueller, Robert Sonntag, et al.
Der Orthopade
|
July 13, 2021
[Typing and particle analysis of squeaking hip endoprostheses : First histopathological analysis to examine the squeaking pathogenesis of ceramic-on-ceramic bearings]
Stephanie Eiden, Therese Bormann, Jan Philippe Kretzer, et al.
Journal of the Mechanical Behavior of Biomedical Materials
|
June 10, 2022
Taper corrosion in total hip arthroplasty - How to assess and which design features are crucial?
Ulrike Mueller, Therese Bormann, Stefan Schroeder, et al.
Bone & Joint Research
|
June 17, 2026
Subluxation-induced liner adhesion and the effect of impaction to prevent liner dislocation in ceramic hip arthroplasty
Maximilian Uhler, Mareike Schonhoff, Sebastian Jäger, et al.
Orthopadie (Heidelberg, Germany)
|
June 4, 2024
[Tribology in arthroplasty : Friction and wear, a key to a long lifetime]
Joachim Döring, Therese Bormann, Adrian Buchholz, et al.
Journal of the Mechanical Behavior of Biomedical Materials
|
February 12, 2022
Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty
Phuong Thao Mai, Therese Bormann, Ulrike Müller, et al.
Materials (Basel, Switzerland)
|
November 7, 2020
Short-Term Heat Treatment of Ti6Al4V ELI as Implant Material
Phuong Thao Mai, Therese Bormann, Robert Sonntag, et al.
Page
of 3