Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Filters

Wolfgang Kainz

Showing results (1-10 of 68) with videos related to

Pageof 7
Sort By:
Neuromodulation : Journal of the International Neuromodulation Society|December 14, 2011
Response to shellock et Al. "Vagus nerve stimulation therapy system: in vitro evaluation of magnetic resonance imaging-related heating and function at 1.5 and 3 tesla"Wolfgang Kainz
Journal of Magnetic Resonance Imaging : JMRI|August 31, 2007
MR heating tests of MR critical implantsWolfgang Kainz
Neuromodulation : Journal of the International Neuromodulation Society|December 14, 2011
Response to shellockWolfgang Kainz
Biomedical Engineering Online|October 16, 2004
Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head modelsBrian B Beard, Wolfgang Kainz
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference|January 18, 2020
Modeling RF-Induced Power Deposition and Temperature Rise of Coaxial Leads with Helical WiresMikhail Kozlov, Marc Horner, Wolfgang Kainz
Magma (New York, N.Y.)|November 21, 2019
Modeling radiofrequency responses of realistic multi-electrode leads containing helical and straight wiresMikhail Kozlov, Marc Horner, Wolfgang Kainz
Biomedical Engineering Online|May 30, 2003
Electromagnetic interference of GSM mobile phones with the implantable deep brain stimulator, ITREL-IIIWolfgang Kainz, François Alesch, Dulciana Dias Chan
Magnetic Resonance in Medicine|August 31, 2019
Wire-based sternal closure: MRI-related heating at 1.5 T/64 MHz and 3 T/128 MHz based on simulation and experimental phantom studyJianfeng Zheng, Meiqi Xia, Wolfgang Kainz, et al.
The Open Biomedical Engineering Journal|November 2, 2011
Wireless Coexistence and EMC of Bluetooth and 802.11b Devices in Controlled Laboratory SettingsSeth Seidman, Wolfgang Kainz, Paul Ruggera, et al.
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference|October 25, 2017
Investigating the effect of coil model losses on computational electromagnetic exposure of an ASTM phantom at 64 MHz MRIMikhail Kozlov, Marc Horner, Wolfgang Kainz, et al.
Pageof 7

Showing results (1-10 of 68) with videos related to

Sort By:
Pageof 7
Neuromodulation : Journal of the International Neuromodulation Society|December 14, 2011
Response to shellock et Al. "Vagus nerve stimulation therapy system: in vitro evaluation of magnetic resonance imaging-related heating and function at 1.5 and 3 tesla"Wolfgang Kainz
Journal of Magnetic Resonance Imaging : JMRI|August 31, 2007
MR heating tests of MR critical implantsWolfgang Kainz
Neuromodulation : Journal of the International Neuromodulation Society|December 14, 2011
Response to shellockWolfgang Kainz
Biomedical Engineering Online|October 16, 2004
Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head modelsBrian B Beard, Wolfgang Kainz
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference|January 18, 2020
Modeling RF-Induced Power Deposition and Temperature Rise of Coaxial Leads with Helical WiresMikhail Kozlov, Marc Horner, Wolfgang Kainz
Magma (New York, N.Y.)|November 21, 2019
Modeling radiofrequency responses of realistic multi-electrode leads containing helical and straight wiresMikhail Kozlov, Marc Horner, Wolfgang Kainz
Biomedical Engineering Online|May 30, 2003
Electromagnetic interference of GSM mobile phones with the implantable deep brain stimulator, ITREL-IIIWolfgang Kainz, François Alesch, Dulciana Dias Chan
Magnetic Resonance in Medicine|August 31, 2019
Wire-based sternal closure: MRI-related heating at 1.5 T/64 MHz and 3 T/128 MHz based on simulation and experimental phantom studyJianfeng Zheng, Meiqi Xia, Wolfgang Kainz, et al.
The Open Biomedical Engineering Journal|November 2, 2011
Wireless Coexistence and EMC of Bluetooth and 802.11b Devices in Controlled Laboratory SettingsSeth Seidman, Wolfgang Kainz, Paul Ruggera, et al.
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference|October 25, 2017
Investigating the effect of coil model losses on computational electromagnetic exposure of an ASTM phantom at 64 MHz MRIMikhail Kozlov, Marc Horner, Wolfgang Kainz, et al.
Pageof 7