Related Experiment Video
Updated: Jul 12, 2026

Laparoscopic-Assisted Seldinger Technique for Peritoneal Dialysis Catheter Insertion
Published on: May 23, 2025
Laparoscopic peritoneal dialysis catheter insertion using a Quinton percutaneous insertion kit
Stephen P Haggerty1, Tallal M Zeni, Mike Carder
1Department of Surgery, Evanston Northwestern Healthcare, Evanston, Illinois, USA. haggertys@ameritech.net
Insights
Laparoscopic peritoneal dialysis (PD) catheter insertion using a Quinton kit is safe and effective. This technique minimizes PD catheter dysfunction by allowing optimal tip placement and necessary surgical interventions.
Area of Science:
- Nephrology
- Minimally Invasive Surgery
Background:
- Peritoneal dialysis (PD) is a vital renal replacement therapy.
- Catheter dysfunction is a significant complication affecting PD efficacy.
- Minimizing PD catheter dysfunction is crucial for successful long-term treatment.
Purpose of the Study:
- To evaluate a unique laparoscopic technique for peritoneal dialysis (PD) catheter insertion.
- To assess the safety, reproducibility, and effectiveness of this minimally invasive approach.
- To determine if this method can reduce the incidence of PD catheter dysfunction.
Main Methods:
- Retrospective review of patients undergoing laparoscopic PD catheter placement.
- Utilized a Quinton percutaneous insertion kit for catheter placement.
- Data collected from July 2000 to December 2004, with a mean follow-up of 17 months.
Main Results:
- Thirty-one laparoscopic PD catheters were successfully placed.
- Mean operative time was 52 minutes.
- Low rate of late complications, including 6.5% catheter dysfunction and 1 case of abdominal pain requiring removal.
Conclusions:
- Laparoscopic PD catheter insertion with a Quinton kit is a safe and effective procedure.
- The technique facilitates optimal catheter tip placement in the pelvis.
- This approach allows for necessary surgical interventions like adhesiolysis and omentectomy, leading to reduced PD catheter dysfunction.
Objective:
We assessed a unique technique of laparoscopic peritoneal dialysis (PD) catheter insertion which can minimize catheter dysfunction.
Methods:
We performed a retrospective review of patients undergoing laparoscopic PD catheter placement with a Quinton percutaneous insertion kit between July 2000 and December 2004.
Results:
Thirty-one catheters were placed laparoscopically. The mean operating time was 52 minutes. Adhesiolysis was required in 9 (29%) and omentectomy or omentopexy in 3 (10%) cases. Late complications included catheter dysfunction in 2 patients (6.5%), debilitating abdominal pain requiring catheter removal in 1 patient, and 1 trocar-site hernia. The mean follow-up was 17 months.
Conclusions:
Laparoscopic PD catheter insertion using a Quinton percutaneous insertion kit is safe, reproducible, and effective. It facilitates placement of the catheter tip into the pelvis and allows adhesiolysis, omentectomy, or omentopexy when necessary. Utilization of this technique results in a low rate of PD catheter dysfunction.
Related Concept Videos
Peritoneal Dialysis I: Introduction and Procedure
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Peritoneal Dialysis III: Nursing Management
Hemodialysis I: Introduction
Hemodialysis II: Procedure and Complications