Effect of storage on p63 immunohistochemistry: a time-course study

Holly N Burford1, Amy L Adams, Omar Hameed

  • 1Department of Pathology, University of Alabama School of Medicine, Birmingham, AL 35294-6823, USA.

Insights

Storage of unstained slides negatively impacts p63 immunohistochemistry staining intensity. This time-dependent decline, evident within two weeks, affects diagnostic accuracy in surgical pathology and research.

Area of Science:

  • Pathology
  • Immunohistochemistry
  • Oncology

Background:

  • Immunohistochemistry (IHC) staining intensity can be affected by unstained slide storage.
  • The impact of storage on p63 antigen staining intensity is not well-documented.

Purpose of the Study:

  • To evaluate the effect of storage duration on p63 immunohistochemical staining intensity.
  • To determine the time course of staining decline in unstained p63 slides.

Main Methods:

  • A time-course study was conducted on breast lesion slides.
  • Slides were stained for p63 at baseline and after 2, 4, and 8 weeks of room temperature storage.
  • A p63 intensity score was calculated based on staining intensity and percentage of positive myoepithelial cells.

Main Results:

  • A progressive decline in p63 staining intensity score was observed over time.
  • Statistically significant differences in staining intensity were found between day 0 and 2 weeks (P=0.037), and 2 and 4 weeks (P=0.001).
  • The decline between 4 and 8 weeks was not statistically significant (P=0.075).

Conclusions:

  • Unstained slide storage leads to a time-dependent decrease in p63 immunostaining intensity.
  • This decline is detectable as early as 2 weeks and persists up to 8 weeks.
  • Consideration of storage time is crucial for accurate interpretation of p63 immunostains in diagnostics and research.