[Pericardial liquid layer as an occasional finding in internal echography. Normal patterns and pathologic limits]
F Angelini1, A Bulzacchi, F Corbetti
1II Servizio Radiologico, Ospedale Civile, Padova.
Insights
Pericardial fluid is common during abdominal ultrasounds but usually harmless. Fluid less than 10 mm thick typically has no clinical relevance, unlike larger effusions.
Area of Science:
- Cardiology
- Radiology
- Medical Imaging
Background:
- Pericardial fluid is frequently an incidental finding during abdominal ultrasound (US).
- Establishing normality ranges for incidental pericardial fluid is crucial for accurate diagnosis.
- Previous studies have not clearly defined the clinical significance of small pericardial fluid volumes detected incidentally.
Purpose of the Study:
- To determine the normality range for incidental pericardial fluid detected during upper abdominal US.
- To assess the clinical relevance of pericardial fluid thickness identified incidentally.
Main Methods:
- 500 patients undergoing liver US were evaluated for pericardial fluid.
- Thickness of pericardial fluid was measured in positive cases.
- Cardiologic evaluation (clinical exam, ECG, echocardiography) was performed for patients with fluid thickness 5-9 mm (n=20) and >10 mm (n=6).
Main Results:
- Pericardial fluid was detected in 20.8% of patients.
- Fluid thickness <10 mm was common and clinically insignificant.
- Pericardial fluid >10 mm was associated with high clinical relevance and often extended around the heart.
Conclusions:
- Incidental pericardial fluid <10 mm thickness on abdominal US is a common, benign finding.
- Pericardial fluid >10 mm warrants further cardiologic investigation due to potential clinical significance.
- Abdominal US can serve as an initial screening tool for detecting potentially significant pericardial effusions.
Abstract:
A small amount of fluid in the pericardial sac is often observed incidentally during upper abdomen US studies. In order to assess the normality range for this finding, 500 patients undergoing liver US were evaluated for the presence of pericardial fluid, the thickness of which was subsequently measured in positive cases. In a group of 20 patients with pericardial fluid thickness ranging 5-9 mm and in 6 cases with pericardial effusion greater than 10 mm, cardiologic evaluation was performed (clinical examination, ECG, echocardiography). Pericardial fluid was quite a common finding (20.8%) which had no clinical relevance when less than 10 mm. On the contrary, its clinical relevance was high when greater than 10 mm, and extending around the heart.
Related Concept Videos
Location and Orientation of the Heart
Layers of the Heart Wall
The myocardium, the thickest layer, consists of cardiac muscle cells interconnected by intercalated discs and crisscrossing connective tissue fibers. These muscle fibers contract...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Pericarditis II: Clinical Features and Diagnostic Tests