Investigation into low-level anti-rubella virus IgG results reported by commercial immunoassays

Wayne Dimech1, Nilukshi Arachchi, Jingjing Cai

  • 1NRL, Melbourne Australia, Victoria, Australia. wayne@nrl.gov.au

Insights

Commercial anti-rubella virus IgG assays show poor standardization despite calibration against a WHO standard. This study reveals significant variability in results, questioning the relevance of current quantification methods for rubella virus IgG.

Area of Science:

  • Immunology
  • Virology
  • Clinical Diagnostics

Background:

  • Commercial anti-rubella virus IgG assays have been calibrated to a WHO International Standard since the 1980s, with results reported in IU/ml.
  • Despite this standardization effort, concerns exist regarding the consistency and comparability of results across different commercial immunoassays (CIAs).

Purpose of the Study:

  • To evaluate the concordance and correlation of quantitative results from multiple commercial anti-rubella virus IgG immunoassays (CIAs).
  • To assess the diagnostic performance (sensitivity and specificity) of CIAs compared to a reference standard.
  • To investigate the impact of long-term calibration on the standardization of rubella virus IgG quantification.

Main Methods:

  • Five different commercial immunoassays (CIAs) were used to test 100 patient samples each, yielding 500 quantitative results.
  • Results were compared against an in-house enzyme immunoassay (IH-EIA) calibrated with the WHO standard.
  • Samples were also screened using hemagglutination inhibition assay (HAI) and immunoblot (IB) assays to establish a reference negative/positive status.

Main Results:

  • Concordance between CIA qualitative results and the assigned status varied significantly, ranging from 50.0% to 97.8%.
  • Receiver operating characteristic analysis showed estimated sensitivity and specificity ranging from 70.2% to 100%.
  • Poor correlation (R(2) from 0.002 to 0.413) was observed between quantitative CIA results and the IH-EIA, indicating a lack of standardization.

Conclusions:

  • Commercial anti-rubella virus IgG assays exhibit poor standardization, with significant variability in quantitative results despite using the same international standard.
  • The current level of standardization challenges the clinical relevance of quantifying anti-rubella virus IgG using existing commercial assays.
  • Reevaluation of the necessity and methodology for quantifying anti-rubella virus IgG may be warranted for the scientific community.