Basophil Activation Test for Investigation of IgE-Mediated Mechanisms in Drug Hypersensitivity
Published on: September 16, 2011
Flow cytometric analysis of drug-Induced basophil histamine release
N Cop1, A P Uyttebroek1, V Sabato1
1Department of Immunology, Allergology, Rheumatology, Faculty of Medicine and Health Science, University of Antwerp, Antwerp University Hospital, Antwerpen, 2610, Belgium.
Insights
The HistaFlow® technique reliably quantifies histamine release from individual basophils, proving effective for studying drug-induced hypersensitivity reactions and immediate responses.
Area of Science:
- Immunology
- Allergy
- Clinical Cytometry
Background:
- Histamine release is crucial in allergic reactions.
- Multicolor flow cytometry offers single-cell analysis of histamine release via HistaFlow®.
- Current clinical applications of HistaFlow® are limited.
Purpose of the Study:
- To validate HistaFlow® for quantifying IgE-mediated basophil responses to rocuronium.
- To assess HistaFlow®'s reliability in detecting drug-specific basophil activation.
- To explore HistaFlow®'s potential in studying less potent basophil activators.
Main Methods:
- Enzyme affinity method (HistaFlow®) using multicolor flow cytometry.
- In vitro basophil activation tests on 10 patients and 3 controls.
- Stimulation with rocuronium at 0.16 and 1.6 mmol/L.
Main Results:
- HistaFlow® detected significant basophil activation (11-86% CD63+ cells) and histamine release (68-100%) in patients.
- No basophil activation was observed in control individuals.
- The technique demonstrated reliability in quantifying histamine release in response to rocuronium.
Conclusions:
- HistaFlow® is a reliable tool for studying single-cell histamine release in response to drugs.
- The technique may not be directly applicable for diagnosing rocuronium allergy.
- HistaFlow® shows promise for future research into immediate drug hypersensitivity mechanisms.
Abstract:
Histamine and its release can be studied by multicolor flow cytometry on a single cell level by an enzyme affinity method (HistaFlow®). However, for the time-being, the clinical and scientific application of the HistaFlow® technique remains limited. This study aims at verifying the reliability of the HistaFlow® as an instrument to quantify IgE-mediated basophil responses to drugs, i.e., rocuronium, which are believed to be less potent basophil activators than large proteinaceous allergens. Ten patients and three exposed control individuals were included in this study. Each subject underwent in vitro basophil activation tests (HistaFlow®) with 0.16 and 1.6 mmol/L rocuronium. Patients showed an activation of basophils ranging from 11 to 86% of CD63 positive basophils and a median histamine release per cell from 68 to 100% after stimulation with an optimal concentration of 1.6 mmol/L rocuronium. For the control individuals no activation was demonstrable. This study confirms that the HistaFlow® technique is a reliable tool to study histamine release by individual cells in response to drugs. Although the HistaFlow® technique will probably not add to the diagnostic management of rocuronium allergy, our findings suggest that the technique could constitute an important asset for future studies on the pathomechanism(s) of immediate drug hypersensitivity reactions. © 2015 International Clinical Cytometry Society.