Related Experiment Video
Updated: Nov 28, 2025

Flow-pattern Guided Fabrication of High-density Barcode Antibody Microarray
Published on: January 6, 2016
Sandwich-Based Antibody Arrays for Protein Detection
Ying Qing Mao1, Brianne Petritis2, Ruo-Pan Huang2,3,4,5
1RayBiotech Life, Peachtree Corners, GA, USA. mike@raybiotech.com.
Insights
This study introduces a rapid, 1-day method for processing samples using quantitative sandwich-based antibody arrays. This fluorescence-based technique allows for simultaneous detection of multiple proteins, offering a cost-effective alternative to traditional single-protein assays.
Area of Science:
- Biochemistry
- Immunotechnology
- Proteomics
Background:
- Sandwich-based antibody arrays allow for multiplexed protein detection.
- These arrays offer a time- and cost-effective alternative to single-plex assays.
- The "sandwich" technique involves a capture antibody and a detection antibody.
Purpose of the Study:
- To describe a streamlined 1-day procedure for sample processing.
- To utilize quantitative sandwich-based antibody arrays on a glass substrate.
- To enable fluorescence-based detection of multiple proteins.
Main Methods:
- Development of a 1-day protocol for sample processing.
- Application of quantitative sandwich-based antibody arrays.
- Utilizing fluorescence for protein detection on a glass substrate.
- Processing of biological samples like serum and cell lysates.
Main Results:
- Successful implementation of a 1-day procedure.
- Demonstration of multiplexed protein detection capabilities.
- Quantitative analysis of proteins in serum and cell lysates.
Conclusions:
- The described method provides an efficient and cost-effective approach for multiplexed protein analysis.
- This 1-day protocol facilitates rapid biomarker discovery and validation.
- The fluorescence-based antibody array platform is suitable for various biological samples.
Abstract:
Sandwich-based antibody arrays enable the detection of multiple proteins simultaneously, thus offering a time- and cost-effective alternative to single-plex platforms. The protein of interest is "sandwiched" between an antibody that captures it to the array and a second antibody that is used for detection. Here we describe a 1-day procedure to process samples, such as serum or cell lysates, with a quantitative sandwich-based antibody array on a glass substrate using fluorescence.
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.