Determining the optimal number of in vivo confocal microscopy (IVCM) images for quantifying corneal immune cell (IC) density is crucial. This study found 12 images for central cornea and 7 for peripheral cornea ensure accuracy, while subjective selection methods lack consistency.

Area of Science:

  • Ophthalmology
  • Cell Biology
  • Medical Imaging

Background:

  • In vivo confocal microscopy (IVCM) is vital for quantifying corneal immune cell (IC) density in clinical research.
  • Current practices often use arbitrary sample sizes for IVCM images, lacking evidence-based guidance for reliable IC density estimation.
  • Establishing a standardized image sample size is essential for consistent and accurate clinical study outcomes.

Purpose of the Study:

  • To determine the optimal number of randomly selected IVCM images for accurate quantification of corneal epithelial IC density in central and peripheral cornea.
  • To evaluate the consistency and precision of subjective image selection methods (three representative images) compared to random selection.

Main Methods:

  • Utilized all combinations of 2-15 non-overlapping IVCM images from 20 healthy participants to derive IC density estimates.
  • Defined the 'true mean' IC density by averaging quantifications from 16 images.
  • Assessed accuracy using mean ratios against the true mean and evaluated observer consistency with intraclass correlation coefficients (ICCs).

Main Results:

  • 12 randomly selected IVCM images yielded an IC density estimate within 30% of the true mean 95% of the time for the central cornea.
  • Seven randomly selected IVCM images provided equivalent precision for the peripheral cornea.
  • Subjective selection of 'three representative images' showed poor inter-observer consistency (ICC <0.5) and similar precision to random selection.

Conclusions:

  • The study provides evidence-based sample size recommendations for IVCM image selection in corneal IC density quantification.
  • 12 images for central and 7 for peripheral cornea are recommended for achieving reliable IC density estimates.
  • Subjective image selection is less reliable than random selection for consistent and precise IC density quantification.