Evaluation of immunocytochemistry on destained giemsa stained smears as an alternative to conventional technique

Pritika Kushwaha1, Toshali Pandey1, Radhika Agarwal1

  • 1Department of Pathology, Maulana Azad Medical College, New Delhi, India.

Insights

This study found that de-staining May-Grünwald Giemsa (MGG)-stained smears for immunocytochemistry (ICC) is not a reliable alternative to standard ICC. The protocol yielded unsatisfactory results for both pancytokeratin and leukocyte common antigen (LCA) staining.

Area of Science:

  • Pathology
  • Cytology
  • Immunohistochemistry

Background:

  • Establishing immunocytochemical (ICC) staining protocols for May-Grünwald Giemsa (MGG)-stained smears presents challenges.
  • Utilizing pre-stained slides for ICC is desirable for timely diagnoses and patient convenience.

Purpose of the Study:

  • To evaluate and compare the efficacy of MGG-stained smears for ICC after de-staining and rehydration against the standard ICC technique.

Main Methods:

  • A prospective study analyzed 40 Fine Needle Aspiration Cytology (FNAC) samples.
  • Smears were stained with MGG, then de-stained and subjected to ICC for pancytokeratin or leukocyte common antigen (LCA)/CD45.
  • Staining results were semi-quantitatively graded based on intensity, localization, uniformity, counter-staining, and background.

Main Results:

  • The de-staining protocol was inferior to conventional ICC across all evaluated parameters.
  • Optimal staining intensity for pancytokeratin was achieved in only 8% of de-stained smears, compared to 44% for wet-fixed smears.
  • Optimal staining for LCA was achieved in 14.3% of de-stained smears versus 85.7% for wet-fixed smears.

Conclusions:

  • The proposed protocol of using de-stained MGG smears for ICC is not a successful alternative to the conventional technique.
  • This method failed to produce satisfactory results for diagnostic ICC staining.
Abstract

Related Concept Videos

Immunogold Electron Microscopy01:20

Immunogold Electron Microscopy

Immunoelectron microscopy utilizes immunogold labeling of endogenous proteins with specific antibodies to detect and localize these proteins in cells and tissues. The procedure provides insights into the distribution and quantification of protein under different stimulation conditions offering clues about their functions. Conjugating highly electron-dense gold particles with primary or secondary antibodies allow antigen detection on and within cells, with high resolution and specificity.
4.2K
Immunocytochemistry and Immunohistochemistry01:22

Immunocytochemistry and Immunohistochemistry

Immunocytochemistry (ICC) and immunohistochemistry (IHC) are techniques that use antibodies to check for specific proteins or antigens in a sample. The technique was first published by Albert Coons in 1941 to detect the presence of pneumococcal antigen in tissue sections from mice infected with Pneumococcus. Immunocytochemistry helps localization of proteins or antigens in individual cells like blood cells, stem cells, etc., while immunohistochemistry does the same for tissue samples.
These...
11.7K