Comparison of pertechnetate and radioiodine thyroid scintiscans in thyroid disease

E Reschini1, A Catania, C Ferrari

  • 1Service of Nuclear Medicine, Ospedale Maggiore di Milano, Italy.

Journal of Nuclear Biology and Medicine (Turin, Italy : 1991)
|March 1, 1993
PubMed

Insights

Technetium-99m-pertechnetate and iodine-131 scintiscans show high correlation for thyroid imaging. Discrepancies in thyroid nodule detection were rare, with only two major cases indicating organification defects.

Area of Science:

  • Nuclear medicine
  • Endocrinology
  • Radiology

Background:

  • Thyroid scintigraphy is crucial for diagnosing various thyroid conditions.
  • Technetium-99m-pertechnetate and iodine-131 are commonly used radiotracers for thyroid imaging.
  • Comparing the diagnostic utility of these tracers is important for optimizing patient care.

Purpose of the Study:

  • To compare the diagnostic accuracy of technetium-99m-pertechnetate (99mTc) and iodine-131 (131I) scintigraphy in patients with thyroid diseases.
  • To evaluate the concordance and discordance rates between the two imaging modalities, particularly in the detection of thyroid nodules.

Main Methods:

  • A retrospective analysis of 273 patients with diverse thyroid pathologies was conducted.
  • Thyroid scintiscans were performed using 99mTc-pertechnetate at 30 minutes and 131I at 24 hours.
  • Scintigraphic findings, including gland appearance and nodule characteristics (cold, warm, hot), were compared between the two tracers.

Main Results:

  • High overall concordance was observed between 99mTc-pertechnetate and 131I scintiscans.
  • Scans were concordant in all patients without nodules and those with cold nodules.
  • Minor discrepancies occurred in 24 patients with hot/warm nodules; major discrepancies (hot on 99mTc, cold on 131I) were rare, seen in two euthyroid patients with organification defects.

Conclusions:

  • Technetium-99m-pertechnetate and iodine-131 scintigraphy demonstrate a high correlation in evaluating thyroid glands and nodules.
  • The imaging findings suggest that 99mTc-pertechnetate can be a reliable alternative to 131I for routine thyroid scintigraphy.
  • Rare discrepancies may indicate underlying organification defects, warranting further investigation.

Related Concept Videos

Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and the...
Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...