Related Experiment Video
Updated: Aug 16, 2026

A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Comparison of pertechnetate and radioiodine thyroid scintiscans in thyroid disease
E Reschini1, A Catania, C Ferrari
1Service of Nuclear Medicine, Ospedale Maggiore di Milano, Italy.
Insights
Technetium-99m-pertechnetate and iodine-131 scintiscans show high correlation for thyroid imaging. Discrepancies in thyroid nodule detection were rare, with only two major cases indicating organification defects.
Area of Science:
- Nuclear medicine
- Endocrinology
- Radiology
Background:
- Thyroid scintigraphy is crucial for diagnosing various thyroid conditions.
- Technetium-99m-pertechnetate and iodine-131 are commonly used radiotracers for thyroid imaging.
- Comparing the diagnostic utility of these tracers is important for optimizing patient care.
Purpose of the Study:
- To compare the diagnostic accuracy of technetium-99m-pertechnetate (99mTc) and iodine-131 (131I) scintigraphy in patients with thyroid diseases.
- To evaluate the concordance and discordance rates between the two imaging modalities, particularly in the detection of thyroid nodules.
Main Methods:
- A retrospective analysis of 273 patients with diverse thyroid pathologies was conducted.
- Thyroid scintiscans were performed using 99mTc-pertechnetate at 30 minutes and 131I at 24 hours.
- Scintigraphic findings, including gland appearance and nodule characteristics (cold, warm, hot), were compared between the two tracers.
Main Results:
- High overall concordance was observed between 99mTc-pertechnetate and 131I scintiscans.
- Scans were concordant in all patients without nodules and those with cold nodules.
- Minor discrepancies occurred in 24 patients with hot/warm nodules; major discrepancies (hot on 99mTc, cold on 131I) were rare, seen in two euthyroid patients with organification defects.
Conclusions:
- Technetium-99m-pertechnetate and iodine-131 scintigraphy demonstrate a high correlation in evaluating thyroid glands and nodules.
- The imaging findings suggest that 99mTc-pertechnetate can be a reliable alternative to 131I for routine thyroid scintigraphy.
- Rare discrepancies may indicate underlying organification defects, warranting further investigation.
Abstract:
In a retrospective study, thyroid scintiscan with technetium-99m-pertechnetate at 30 minutes was compared with the iodine-131 scan at 24 hours in 273 patients with various thyroid diseases. The pertechnetate scan showed normal or diffusely enlarged thyroid glands in 64 patients, cold nodules in 36, and hot or warm nodules in 173. The radioiodine and pertechnetate scintiscans were concordant in all patients without nodules and in those with cold nodules. Minor discrepancies were observed in 24 patients with hot or warm nodules. Only 2 patients, both euthyroid, showed major discrepancies in which nodules appeared hot with pertechnetate and cold with radioiodine. Sequential scintiscans with radioiodine performed in both of these patients, and a perchlorate test performed in one, demonstrated organification defects in the nodules. The data indicate that there is a high correlation between the results of scintiscans using the two tracers; discrepancies in results with the two imaging techniques were rare.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography