Detección de un intermediario de la oxidación del agua fotosintética

Juergen Clausen1, Wolfgang Junge

  • 1Division of Biophysics, Department of Biology/Chemistry, Universität Osnabrück, D-49069 Osnabrück, Germany. junge@uos.de

Nature
|July 23, 2004
PubMed
Resumen

Los investigadores investigaron la reacción de división del agua en el fotosistema II. Al aumentar la presión de oxígeno, encontraron evidencia de un intermediario estabilizado, lo que sugiere que la reacción puede ocurrir en múltiples pasos, no en uno solo.

Videos de Conceptos Relacionados

UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Oxygenic Photosynthesis01:26

Oxygenic Photosynthesis

Oxygenic photosynthesis is a fundamental process in which light energy is harnessed to drive the oxidation of water, leading to the production of molecular oxygen (O₂), adenosine triphosphate (ATP), and nicotinamide adenine dinucleotide phosphate (NADPH). This process is essential for sustaining aerobic life on Earth and is primarily carried out by cyanobacteria, algae, and plants. The core of oxygenic photosynthesis lies in the thylakoid membranes, where chlorophyll pigments facilitate light...