Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

Sensory Functions of the Skin01:16

Sensory Functions of the Skin

The skin is the largest organ of the human body and plays a crucial role in our sensory perception. It contains a vast network of sensory receptors that contribute to the skin's protective function by perceiving physical, biological, and environmental cues and generating relevant responses.
There are two main categories of receptors on the skin: capsulated and non-capsulated. The non-capsulated ones are mainly the pain receptors. The capsulated ones can be further categorized based on the...

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Alzheimer's disease as a women's health challenge: a call for action on integrative precision medicine approaches.

npj women's health·2024
Same author

Compared to CPAP extubation to non-invasive ventilation is associated with higher risk of bronchopulmonary dysplasia in extremely low birth weight infants.

Journal of neonatal-perinatal medicine·2019
Same author

Practical Approach to Syncope: Identifying causes and underlying conditions.

Canadian family physician Medecin de famille canadien·2011
Same author

[Mechanisms of electrical defibrillation].

Herzschrittmachertherapie & Elektrophysiologie·2009
Same author

[Not Available].

Herzschrittmachertherapie & Elektrophysiologie·2009
Same author

Epicardial wavefronts arise from widely distributed transient sources during ventricular fibrillation in the isolated swine heart.

New journal of physics·2008

Video Experimental Relacionado

Updated: Jul 5, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
16:40

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation

Published on: February 28, 2012

Los campos tridimensionales de gradiente de potencial generados por el catéter intracárdico y los electrodos de

A S Tang1, P D Wolf, Y Afework

  • 1Department of Medicine, Duke University Medical Center, Durham, N.C.

Circulation
|May 1, 1992
PubMed
Resumen

Al investigar las configuraciones de los electrodos de desfibrilación, este estudio encontró que la configuración V----A+P generaba los gradientes de tensión más fuertes a través del corazón. Sin embargo, los campos de gradiente seguían siendo desiguales, lo que indicaba un margen de mejora en la efectividad de la desfibrilación.

Más Videos Relacionados

Three-dimensional Imaging of Nociceptive Intraepidermal Nerve Fibers in Human Skin Biopsies
11:22

Three-dimensional Imaging of Nociceptive Intraepidermal Nerve Fibers in Human Skin Biopsies

Published on: April 29, 2013

An Implantable System For Chronic In Vivo Electromyography
09:52

An Implantable System For Chronic In Vivo Electromyography

Published on: April 21, 2020

Videos de Experimentos Relacionados

Last Updated: Jul 5, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
16:40

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation

Published on: February 28, 2012

Three-dimensional Imaging of Nociceptive Intraepidermal Nerve Fibers in Human Skin Biopsies
11:22

Three-dimensional Imaging of Nociceptive Intraepidermal Nerve Fibers in Human Skin Biopsies

Published on: April 29, 2013

An Implantable System For Chronic In Vivo Electromyography
09:52

An Implantable System For Chronic In Vivo Electromyography

Published on: April 21, 2020

Área de la Ciencia:

  • Fisiología cardiovascular fisiología cardiovascular.
  • Ingeniería biomédica de la ingeniería biomédica.
  • Electrofisiología y electrofisiología.

Sus antecedentes:

  • La optimización de la desfibrilación requiere configuraciones de electrodos que crean gradientes de tensión más grandes y uniformes en todo el corazón.
  • Este estudio evaluó cuatro configuraciones de electrodos sin toracotomía por su capacidad para generar gradientes de choque de desfibrilación efectivos.

Objetivo del estudio:

  • Para determinar la magnitud de los campos de gradiente de choque generados por cuatro configuraciones de electrodos sin toracotomía para la desfibrilación.
  • Para comparar la efectividad de diferentes colocaciones de electrodos en la creación de gradientes de voltaje a través del corazón.

Principales métodos:

  • Se utilizaron seis perros, con electrodos colocados en el ventrículo derecho (V), la aurícula derecha (A) y en el tórax lateral izquierdo (P).
  • Se registraron potenciales de choque de 128 electrodos dentro de los ventrículos y las aurículas durante la diástole.
  • Se calcularon gradientes potenciales para cuatro configuraciones: V----A, V----P, V----A+P y V+A----P.

Principales resultados:

  • La configuración V----A+P generalmente producía gradientes de tensión más altos a lo largo de los ventrículos en comparación con V----A, V----P o V+A----P.
  • La configuración V+A----P dio como resultado el gradiente de potencial máximo más bajo entre las configuraciones probadas.
  • Se observó que los campos de gradiente eran desiguales a través de los ventrículos para las configuraciones que involucran el catéter solo o combinado con el electrodo de parche.

Conclusiones:

  • Es factible estimar los campos tridimensionales del gradiente de choque.
  • La configuración V----A+P produjo los gradientes más altos, mientras que V+A----P produjo el gradiente más bajo.
  • La desigualdad observada en los campos de gradiente a través de los ventrículos sugiere limitaciones en las configuraciones actuales sin toracotomía para lograr una desfibrilación uniforme.