Jove
Visualize
Contáctanos

Videos de Conceptos Relacionados

Interference and Diffraction02:18

Interference and Diffraction

28.7K
Interference is a characteristic phenomenon exhibited by waves. When two electromagnetic waves interact with their peaks and troughs coinciding, a resulting wave with enhanced amplitude is produced. This is known as constructive interference. In this case, the two waves interacting are in phase with each other.
28.7K
IR Spectrometers01:25

IR Spectrometers

3.1K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
3.1K
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

2.0K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
2.0K
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

2.1K
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
2.1K
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

2.3K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.3K
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

785
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
785

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Quantitative flow ratio for assessment of donor vessel in patients with chronic total occlusions.

BMC cardiovascular disorders·2026
Same author

A Multicenter Feasibility and Safety Study of a Novel Hybrid IVUS-OCT Imaging System.

JACC. Asia·2025
Same author

Design, synthesis and antitumor activity evaluation of novel modified 18β-glycyrrhetinate derivatives as PPARγ agonists.

Bioorganic chemistry·2025
Same author

Test-retest reliability of resting-state EEG intrinsic neural timescales.

Cerebral cortex (New York, N.Y. : 1991)·2025
Same author

Lattice Light Shift Evaluations in a Dual-Ensemble Yb Optical Lattice Clock.

Physical review letters·2025
Same author

Predictive Value of Combining Angio-Based Index of Microcirculatory Resistance and Fractional Flow Reserve in Patients with STEMI.

The Canadian journal of cardiology·2025
Same journal

Incoming US science academy chief vows to 'double down' on research.

Nature·2026
Same journal

Author Correction: Synthesis of enantioenriched atropisomers by biocatalytic deracemization.

Nature·2026
Same journal

Electrodeposited self-assembled molecules for perovskite photovoltaics.

Nature·2026
Same journal

Neutrino's nursery found: the 'Shadow Blaster'.

Nature·2026
Same journal

Dementia risk in middle-aged people linked to a blood protein.

Nature·2026
Same journal

Daily briefing: What's really happening with trust in science.

Nature·2026
Ver todos los artículos relacionados
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Video Experimental Relacionado

Updated: May 4, 2026

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

8.8K

Se trata de un interferómetro de dispersión cuántica.

Russell A Hart1, Xinye Xu, Ronald Legere

  • 1Department of Physics, The Pennsylvania State University, University Park, Pennsylvania 16802, USA.

Nature
|April 20, 2007
PubMed
Resumen
Este resumen es generado por máquina.

Los investigadores midieron con precisión las interacciones atomo-atomo ultrafrías utilizando un nuevo interferómetro atómico. Este avance permite la detección independiente de la densidad de los cambios de fase de la dispersión cuántica, crucial para las aplicaciones de la física atómica.

Más Videos Relacionados

Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source
12:19

Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source

Published on: April 4, 2017

7.9K
A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
07:56

A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference

Published on: September 5, 2019

9.8K

Videos de Experimentos Relacionados

Last Updated: May 4, 2026

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

8.8K
Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source
12:19

Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source

Published on: April 4, 2017

7.9K
A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
07:56

A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference

Published on: September 5, 2019

9.8K

Área de la Ciencia:

  • Física atómica es la física atómica.
  • La mecánica cuántica es la mecánica cuántica.
  • La óptica cuántica es la óptica cuántica.

Sus antecedentes:

  • Los cambios de fase de dispersión cuántica gobiernan las interacciones de átomos ultrafríos.
  • La medición precisa es vital para los condensados de Bose-Einstein, los relojes atómicos y las resonancias de Feshbach.
  • Los métodos anteriores estaban limitados por mediciones dependientes de la densidad.

Objetivo del estudio:

  • Desarrollar un nuevo método para medir con precisión los desplazamientos de fase de la dispersión cuántica.
  • Para permitir mediciones independientes de la densidad de las interacciones atomo-atomo ultrafrías.
  • Explorar aplicaciones en estudios de variación de constantes fundamentales.

Principales métodos:

  • Utilizó un nuevo interferómetro atómico para detectar cambios de fase de dispersión cuántica.
  • Realizó mediciones de reloj atómico en las funciones de onda atómicas dispersas.
  • Se logró una medición independiente de la densidad de las diferencias de desplazamiento de fase.

Principales resultados:

  • Se detectaron con éxito cambios de fase de dispersión cuántica de átomos individuales.
  • Medido con precisión la diferencia en los cambios de fase de onda s para dos estados de reloj.
  • Demostró una técnica de medición independiente de la densidad.

Conclusiones:

  • El nuevo interferómetro atómico permite la medición directa y precisa de las interacciones atomo-atomo ultrafrías.
  • Este método abre nuevas vías para el estudio de la física fundamental, incluidas las variaciones temporales de las constantes.