Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

Atomic Absorption Spectroscopy: Overview01:27

Atomic Absorption Spectroscopy: Overview

Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Fluorescence Spectroscopy01:29

Atomic Fluorescence Spectroscopy

Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which are...

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Memo to members.

Science (New York, N.Y.)·1989
Same author

AAAS Annual Meeting: Preconvention Program.

Science (New York, N.Y.)·1987
Same author

AAAS Annual Meeting Philadelphia, 25-30 May 1986.

Science (New York, N.Y.)·1986
Same author

Philadelphia: where it all began.

Science (New York, N.Y.)·1986
Same author

Thrombolytic therapy in the coronary care unit.

Catheterization and cardiovascular diagnosis·1986
Same author

Intracoronary streptokinase therapy in the coronary care unit for acute myocardial infarction.

Clinical cardiology·1984

Video Experimental Relacionado

Updated: Jul 8, 2026

Analysis of SEC-SAXS data via EFA deconvolution and Scatter
10:59

Analysis of SEC-SAXS data via EFA deconvolution and Scatter

Published on: January 28, 2021

Reunión anual de la AAAS en Filadelfia, del 25 al 30 de mayo de 1986.

A Herschman

    Science (New York, N.Y.)
    |February 28, 1986
    PubMed
    Resumen

    No abstract available in PubMed .

    Más Videos Relacionados

    On-Chip Crystallization and Large-Scale Serial Diffraction at Room Temperature
    07:42

    On-Chip Crystallization and Large-Scale Serial Diffraction at Room Temperature

    Published on: March 11, 2022

    Curation of Computational Chemical Libraries Demonstrated with Alpha-Amino Acids
    08:21

    Curation of Computational Chemical Libraries Demonstrated with Alpha-Amino Acids

    Published on: April 13, 2022

    Videos de Experimentos Relacionados

    Last Updated: Jul 8, 2026

    Analysis of SEC-SAXS data via EFA deconvolution and Scatter
    10:59

    Analysis of SEC-SAXS data via EFA deconvolution and Scatter

    Published on: January 28, 2021

    On-Chip Crystallization and Large-Scale Serial Diffraction at Room Temperature
    07:42

    On-Chip Crystallization and Large-Scale Serial Diffraction at Room Temperature

    Published on: March 11, 2022

    Curation of Computational Chemical Libraries Demonstrated with Alpha-Amino Acids
    08:21

    Curation of Computational Chemical Libraries Demonstrated with Alpha-Amino Acids

    Published on: April 13, 2022