High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation00:57

High-Performance Liquid Chromatography: Instrumentation

High-performance liquid chromatography, or HPLC, is an analytical technique that separates liquid samples under high pressures. An HPLC instrument consists of glass bottles for storing solvents called mobile phase reservoirs. HPLC-grade solvents are used to maintain high purity, and the dissolved gases are removed using a degasser, such as a vacuum pumping system or sparging with helium. The solvents are then pumped into the analytical column using a screw-driven syringe or reciprocating pumps.
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Re: Assessing the effects of manual dexterity and playing computer games on catheter-wire manipulation for inexperienced operators.

Clinical radiology·2017
Same author

Nucleation and growth of copper selective-area atomic layer deposition on palladium nanostructures.

The Journal of chemical physics·2017
Same author

Objective model using only gender, age and medication list predicts in-hospital morbidity after elective surgery.

British journal of anaesthesia·2017
Same author

Obesity and the extent of liver damage among adult New Zealanders: findings from a national survey.

Obesity science & practice·2016
Same author

Sigmoid Volvulus and Chronic Colonic Schistosomiasis: Causal or Casual Link.

The West Indian medical journal·2015
Same author

Incidental splenic littoral cell angioma complicating a case of Rolon cancer: A case report.

The Gulf journal of oncology·2015

Video Experimental Relacionado

Updated: Jul 11, 2026

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
08:01

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection

Published on: December 15, 2015

Detección multicanal en cromatografía líquida de alto rendimiento.

J C Miller, S A George, B G Willis

    Science (New York, N.Y.)
    |October 15, 1982
    PubMed
    Resumen
    Este resumen es generado por máquina.

    Un nuevo detector ultravioleta visible para cromatografía líquida de alto rendimiento utiliza una matriz de fotodiodos para la adquisición simultánea de datos de longitud de onda. Este sistema permite el procesamiento en tiempo real de múltiples señales y el análisis espectral rápido para la determinación de la pureza máxima.

    Más Videos Relacionados

    Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
    06:25

    Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns

    Published on: April 26, 2016

    Videos de Experimentos Relacionados

    Last Updated: Jul 11, 2026

    Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
    08:01

    Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection

    Published on: December 15, 2015

    Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
    06:25

    Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns

    Published on: April 26, 2016

    Área de la Ciencia:

    • Química Analítica La Química Analítica es la
    • La cromatografía es la cromatografía.
    • La espectroscopia es una técnica de espectroscopia.

    Sus antecedentes:

    • La cromatografía líquida de alto rendimiento (HPLC) es una técnica de separación crítica.
    • La detección UV-Vis se utiliza ampliamente en HPLC para la identificación y cuantificación de compuestos.
    • Existen limitaciones en los detectores tradicionales con respecto a la velocidad y la adquisición espectral.

    Objetivo del estudio:

    • Introducir un nuevo sistema de detección UV-Vis para HPLC utilizando una matriz de fotodiodos lineales.
    • Para permitir la adquisición espectral simultánea a través de un amplio rango de longitudes de onda.
    • Para mejorar las capacidades de procesamiento de datos en tiempo real para análisis cromatográficos complejos.

    Principales métodos:

    • Se empleó una matriz de fotodiodos lineales como el fotodetector central.
    • El sistema integró conceptos de red de computadoras para el procesamiento simultáneo de señales en tiempo real.
    • Se implementaron tiempos de respuesta variables (tan bajos como 0,040 s) y selección de ancho de banda (4400 nm).
    • Se logró una rápida adquisición espectral (10 ms).

    Principales resultados:

    • Adquisición simultánea de datos de intensidad de luz de 190 a 600 nm.
    • Procesamiento en tiempo real de hasta ocho señales cromatográficas diferentes.
    • Capacidad demostrada para técnicas rápidas de HPLC con mejores relaciones señal-ruido.
    • Caracterización cualitativa exitosa en múltiples puntos en un solo pico sin comprometer la integridad de la señal.

    Conclusiones:

    • El nuevo sistema de detección UV-Vis basado en fotodiodos avanza significativamente las capacidades de HPLC.
    • Facilita el análisis rápido de pureza de pico y la reducción eficiente de los datos posteriores al análisis.
    • El sistema soporta métodos cromatográficos avanzados que requieren información espectral rápida.