Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Engineered iMSCs delivering wild-type IL-2 achieve dose-sparing tumor control via CD25-dependent CD8<sup>+</sup> T-cell activation.

BMC medicine·2026
Same author

A comprehensive landscape of human organ N-glycoproteome.

Nature communications·2026
Same author

Amino-blocking sialic acid linkage specific alkylamidation for qualitative and quantitative analysis of sialylated glycoproteins.

Analytica chimica acta·2026
Same author

Integrative Quantitative Proteomics and N-Glycoproteomics Reveal Age-Processing of N-Glycosylation in Caenorhabditis elegans.

Proteomics·2026
Same author

Steering semi-flexible molecular diffusion model for structure-based drug design with reinforcement learning.

Science advances·2026
Same author

Ultrafast peptide preparation brings shotgun proteomics into the minute era.

Analytica chimica acta·2026

Video Experimental Relacionado

Updated: Jul 3, 2026

Imaging of Biological Tissues by Desorption Electrospray Ionization Mass Spectrometry
06:21

Imaging of Biological Tissues by Desorption Electrospray Ionization Mass Spectrometry

Published on: July 12, 2013

¿La ionización por electrospray produce estructuras en fase gaseosa o en fase líquida?

Zhixin Tian1, Steven R Kass

  • 1Department of Chemistry, University of Minnesota, Minneapolis, Minnesota 55455, USA.

Journal of the American Chemical Society
|July 30, 2008
PubMed
Resumen

La ionización por electrospray de la tirosina produce diferentes estructuras iónicas basadas en el disolvente. Las mezclas de metanol/agua favorecen el equilibrio de la fase gaseosa, mientras que las soluciones de acetonitrilo producen principalmente iones carboxilatos.

Más Videos Relacionados

Characterizing Bacterial Volatiles using Secondary Electrospray Ionization Mass Spectrometry (SESI-MS)
08:54

Characterizing Bacterial Volatiles using Secondary Electrospray Ionization Mass Spectrometry (SESI-MS)

Published on: June 8, 2011

Videos de Experimentos Relacionados

Last Updated: Jul 3, 2026

Imaging of Biological Tissues by Desorption Electrospray Ionization Mass Spectrometry
06:21

Imaging of Biological Tissues by Desorption Electrospray Ionization Mass Spectrometry

Published on: July 12, 2013

Characterizing Bacterial Volatiles using Secondary Electrospray Ionization Mass Spectrometry (SESI-MS)
08:54

Characterizing Bacterial Volatiles using Secondary Electrospray Ionization Mass Spectrometry (SESI-MS)

Published on: June 8, 2011

Área de la Ciencia:

  • Química analítica Química analítica es la que
  • Química Física es la química física.
  • Espectrometría de masas por espectrometría de masas.

Sus antecedentes:

  • La ionización por electrospray (ESI) es una técnica crucial para el análisis de biomoléculas.
  • La estructura de los iones generados por ESI puede ser influenciada por la composición del disolvente.
  • Comprender los mecanismos de formación de iones es vital para un análisis preciso de la espectrometría de masas.

Objetivo del estudio:

  • Investigar el impacto de los sistemas de disolventes en la composición isomérica de la fase gaseosa de los iones deprotonados de tirosina generados por ionización por electrospray.
  • Para determinar si las relaciones de iones observadas reflejan los equilibrios de la fase líquida o de la fase gaseosa.

Principales métodos:

  • Se empleó la espectrometría de masas de ionización por electrospray (ESI-MS).
  • La tirosina se disolvió en varias mezclas de disolventes, incluyendo metanol/agua y acetonitril/agua.
  • Se analizaron los iones desprotonados ([M-H]-) de la tirosina para determinar sus estructuras isoméricas.

Principales resultados:

  • ESI de tirosina en una mezcla 3:1 de metanol/agua produjo un ion desprotonado ([M-H]-) compuesto por 70% de fenoxido y 30% de iones carboxilato, reflejando el equilibrio de la fase gaseosa.
  • En contraste, las mezclas de acetonitrilo anhidro y acetonitrilo/agua produjeron predominantemente iones carboxilatos (aprox. El 95%). el 95%).
  • La adición de pequeñas cantidades de metanol a los disolventes a base de acetonitrilo cambió la composición iónica hacia la relación de equilibrio de fase gaseosa.

Conclusiones:

  • La estructura isomérica de los iones de tirosina electro rociados depende en gran medida del sistema de disolventes utilizado.
  • La elección del disolvente en ESI-MS puede influir significativamente en la composición iónica observada, reflejando potencialmente los equilibrios de fase gaseosa en lugar de las distribuciones de fase líquida.
  • Este hallazgo tiene implicaciones para la interpretación de los datos de espectrometría de masas y la optimización de las condiciones de ESI para analíticos específicos.