Jove
Visualize
Contáctanos

Videos de Conceptos Relacionados

Microbial Biosensors01:17

Microbial Biosensors

Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Electrostatic Gating of Ionic Conductance through Heterogeneous van der Waals Nanopores.

ACS nano·2026
Same author

Self-grown mycelium in confined geometries as nanofluidic devices.

Nature communications·2026
Same author

Nanopores with dynamic pore opening diameter.

Faraday discussions·2026
Same author

Heterogeneous Multilayer Nanopores via Chemically Tuned Dielectric Breakdown for Single-Molecule Sensing.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

Nanopores with Ionic Memory in Oscillating Ion Current Signals.

Journal of the American Chemical Society·2025
Same author

Modulation of ionic current rectification in short unipolar nanopores.

Journal of colloid and interface science·2025
Same journal

Gas-Responsive Metal-Organic Frameworks for Adaptive Thermal Energy Storage with Tunable Charge-Discharge Temperatures.

Journal of the American Chemical Society·2026
Same journal

Engineering a Thiamine-Dependent Benzoylformate Decarboxylase for Stereodivergent Radical C(sp<sup>3</sup>)-C(sp<sup>3</sup>) Bond Formation.

Journal of the American Chemical Society·2026
Same journal

Accelerated Directional Proton-Coupled Electron Transfer Enabled by Intrinsic Dipole Field in Biomimetic α-Helical Structure.

Journal of the American Chemical Society·2026
Same journal

Alternating Current-Driven Hydrogen Isotope Labeling of Aliphatic Amines Using 1,3-Propanedithiol as an Efficient Hydrogen Atom Transfer Reagent.

Journal of the American Chemical Society·2026
Same journal

Two-Dimensional van der Waals Polar Metal MoOBr<sub>2</sub>.

Journal of the American Chemical Society·2026
Same journal

Negatively Curved Chiral Bilayer Nanographene.

Journal of the American Chemical Society·2026
Ver todos los artículos relacionados
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Video Experimental Relacionado

Updated: Jun 22, 2026

Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions
12:20

Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions

Published on: July 22, 2013

La biosensibilidad con diodos nanofluídicos.

Ivan Vlassiouk1, Thomas R Kozel, Zuzanna S Siwy

  • 1Department of Physics and Astronomy, University of California, Irvine, California 92697, USA.

Journal of the American Chemical Society
|June 11, 2009
PubMed
Resumen
Este resumen es generado por máquina.

Los diodos nanofluídicos permiten nuevos biosensores mediante la detección de la unión del analito a través de cambios en la rectificación de corriente iónica. Esta tecnología permite la detección sensible de moléculas como el ácido poli gamma-D-glutámico (gammaDPGA) y las proteínas.

Más Videos Relacionados

Creating Sub-50 Nm Nanofluidic Junctions in PDMS Microfluidic Chip via Self-Assembly Process of Colloidal Particles
11:13

Creating Sub-50 Nm Nanofluidic Junctions in PDMS Microfluidic Chip via Self-Assembly Process of Colloidal Particles

Published on: March 13, 2016

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
13:42

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation

Published on: September 19, 2017

Videos de Experimentos Relacionados

Last Updated: Jun 22, 2026

Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions
12:20

Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions

Published on: July 22, 2013

Creating Sub-50 Nm Nanofluidic Junctions in PDMS Microfluidic Chip via Self-Assembly Process of Colloidal Particles
11:13

Creating Sub-50 Nm Nanofluidic Junctions in PDMS Microfluidic Chip via Self-Assembly Process of Colloidal Particles

Published on: March 13, 2016

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
13:42

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation

Published on: September 19, 2017

Área de la Ciencia:

  • Nanotecnología La nanotecnología es la nanotecnología.
  • Biosensing es el uso de biosensores.
  • La biofísica es la biofísica.

Sus antecedentes:

  • Los diodos nanofluídicos exhiben características no lineales de corriente-voltaje.
  • La unión del analito a las superficies de los nanoporos altera la carga superficial.
  • Los cambios en la rectificación de corriente iónica pueden indicar la presencia de analito.

Objetivo del estudio:

  • Para explorar las aplicaciones de biosensing de los diodos nanofluídicos.
  • Investigar la detección del analito a través de cambios en la rectificación de corriente iónica.
  • Desarrollar sensores para biomoléculas específicas.

Principales métodos:

  • Modelado y estudios experimentales de diodos nanofluídicos.
  • Utilizando nanoporos cónicos individuales como plataformas de detección.
  • Modificación de nanoporos con anticuerpos para la captura de analito específico.

Principales resultados:

  • Capacidades de biosensores demostradas de los diodos nanofluídicos.
  • Desarrolló un prototipo de sensor para el ácido poligamma-D-glutámico (gammaDPGA) cápsula de Bacillus anthracis.
  • Se crearon con éxito sensores para la avidina y la streptavidina, y se determinaron los puntos isoeléctricos de las proteínas.

Conclusiones:

  • Los diodos nanofluídicos son plataformas efectivas de biosensibilidad.
  • El monitoreo de los cambios en el grado de rectificación es un método de detección viable.
  • Esta tecnología permite la detección sensible y la caracterización de las biomoléculas.