Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

IR and UV–Vis Spectroscopy of Aldehydes and Ketones01:29

IR and UV–Vis Spectroscopy of Aldehydes and Ketones

Infrared spectroscopy, also known as vibrational spectroscopy, is mainly used to determine the types of bonds and functional groups in molecules. In aldehydes and ketones, the carbonyl (C=O) bond shows an absorption around 1710 cm-1. The C=O bond vibration of an aldehyde occurs at lower frequencies than that of a ketone. In addition to the C=O absorption in an aldehyde, the aldehydic C–H bond also gives two peaks in the 2700–2800 cm-1 range. This absorption, coupled with the C=O stretching, is...
Labeling DNA Probes03:31

Labeling DNA Probes

DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
IR and UV–Vis Spectroscopy of Carboxylic Acids01:28

IR and UV–Vis Spectroscopy of Carboxylic Acids

In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for electronic transitions. As a result...
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Enabling Visible and Near-Infrared Dual-Mode Emissions in Polycrystalline Gd<sub>2</sub>Hf<sub>2</sub>O<sub>7</sub> Transparent Ceramics.

Inorganic chemistry·2026
Same author

Unlocking metal-free multicolor thermoluminescence in carbon-dot composites <i>via</i> trap engineering.

Chemical communications (Cambridge, England)·2026
Same author

Microwave-Induced Self-Activated Emission in Spinel Gallate ZnGa<sub>2</sub>O<sub>4</sub> for Dual-Channel Trapping and Detrapping.

Inorganic chemistry·2026
Same author

Realizing Simultaneous UV and Visible Persistent Luminescence by Defect Engineering.

Inorganic chemistry·2026
Same author

Facilitating cryogenic blue persistent luminescence in a glassy matrix.

Materials horizons·2025
Same author

Chiral au nanocluster-porphyrin assemblies enhanced photodynamic disinfection for acidophilic Bacteria.

Journal of colloid and interface science·2025

Video Experimental Relacionado

Updated: May 28, 2026

Real-time In Vitro Monitoring of Odorant Receptor Activation by an Odorant in the Vapor Phase
09:53

Real-time In Vitro Monitoring of Odorant Receptor Activation by an Odorant in the Vapor Phase

Published on: April 23, 2019

Preoxidación para la detección de VOCs por el conjunto de sensores colorimétricos.

Hengwei Lin1, Minseok Jang, Kenneth S Suslick

  • 1Department of Chemistry, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, Illinois 61801, USA.

Journal of the American Chemical Society
|October 5, 2011
PubMed
Resumen

Un nuevo método de preoxidación mejora significativamente la detección de compuestos orgánicos volátiles (COV) utilizando sensores colorimétricos. Esta técnica mejora la sensibilidad y reduce los límites de detección para 20 compuestos orgánicos volátiles en interiores, lo que ayuda a una identificación y un monitoreo precisos.

Más Videos Relacionados

Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
08:23

Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry

Published on: June 14, 2018

Videos de Experimentos Relacionados

Last Updated: May 28, 2026

Real-time In Vitro Monitoring of Odorant Receptor Activation by an Odorant in the Vapor Phase
09:53

Real-time In Vitro Monitoring of Odorant Receptor Activation by an Odorant in the Vapor Phase

Published on: April 23, 2019

Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
08:23

Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry

Published on: June 14, 2018

Área de la Ciencia:

  • Química del medio ambiente Química del medio ambiente
  • Química analítica Química analítica es un campo de estudio de la química analítica.
  • Tecnología de Sensores Tecnología de Sensores

Sus antecedentes:

  • Los compuestos orgánicos volátiles (COV) representan riesgos significativos para la calidad del aire interior.
  • Los métodos actuales para la detección de COV a menudo carecen de sensibilidad para los compuestos menos reactivos.
  • Las matrices de sensores colorimétricos ofrecen potencial para el monitoreo de COV, pero requieren un rendimiento mejorado.

Objetivo del estudio:

  • Desarrollar y evaluar una técnica de preoxidación desechable para mejorar la detección de COV mediante sensores colorimétricos.
  • Para mejorar la sensibilidad y reducir los límites de detección (LOD) para una gama de COVs en interiores.
  • Permitir la identificación y discriminación de los compuestos orgánicos volátiles comunes en interiores en los niveles de exposición relevantes.

Principales métodos:

  • Se utilizó un tubo de preoxidación lleno de ácido crómico en sílice.
  • Las corrientes de vapor que contienen COV se pasaron a través del tubo de preoxidación antes de llegar a una matriz de sensores colorimétricos.
  • Se comparó el rendimiento de la matriz de sensores con y sin preoxidación.

Principales resultados:

  • La técnica de preoxidación aumentó sustancialmente la sensibilidad a los COV menos reactivos.
  • Los límites de detección (LOD) se mejoraron aproximadamente 300 veces en promedio.
  • El sistema detectó, identificó y discriminó con éxito 20 compuestos orgánicos volátiles comunes en interiores a concentraciones IDLH y PEL.
  • Los LOD promedio fueron del 1,4% de los respectivos PEL.

Conclusiones:

  • La preoxidación desechable es un método altamente efectivo para mejorar la detección de COV con sensores colorimétricos.
  • Esta técnica mejora significativamente la capacidad de monitorear los COV en interiores a niveles seguros y peligrosos.
  • El sistema de sensores mejorado proporciona una herramienta sensible y discriminativa para la evaluación de la calidad del aire interior.