Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

Atomic Nuclei: Types of Nuclear Relaxation01:28

Atomic Nuclei: Types of Nuclear Relaxation

430
Nuclear relaxation restores the equilibrium population imbalance and can occur via spin–lattice or spin–spin mechanisms, which are first-order exponential decay processes.
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers...
430
Clot Retraction and Fibrinolysis01:16

Clot Retraction and Fibrinolysis

7.1K
After a fibrin clot is formed, the next step is clot retraction, a vital process facilitated by platelet contractile proteins, such as actin and myosin. These proteins pull the fibrin strands closer together and condense the clot. This action reduces the size of the clot, creating a smaller, denser structure that effectively seals off the damaged vessel. Clot retraction consolidates the clot and helps with wound healing by bringing the edges of the damaged blood vessel closer together.
7.1K

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Dynamic MRI of the placenta.

Placenta·2026
Same author

Other science opportunities at the FCC-ee.

European physical journal plus·2026
Same author

Bright electron bunches from a plasma-wakefield accelerator with a steep density down-ramp.

Nature communications·2026
Same author

Input to the European strategy for particle physics: strong-field quantum electrodynamics.

European physical journal plus·2025
Same author

Plasma-wakefield accelerator simultaneously boosts electron beam energy and brightness.

Nature communications·2025
Same author

Experimental Observation of the Motion of Ions in a Resonantly Driven Plasma Wakefield Accelerator.

Physical review letters·2025

Video Experimental Relacionado

Updated: Oct 1, 2025

Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses
11:20

Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses

Published on: July 2, 2012

15.1K

Tiempo de recuperación de un acelerador de campo de vigilia de plasma

R D'Arcy1, J Chappell2, J Beinortaite3,2

  • 1Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany. richard.darcy@desy.de.

Nature
|March 3, 2022
PubMed
Resumen

Los aceleradores de partículas de alta energía pueden lograr energías más altas utilizando campos de vigilia de plasma. Este estudio muestra que los tiempos de recuperación de plasma permiten velocidades de aceleración de megahertz, haciéndolas factibles para futuras instalaciones.

Más Videos Relacionados

Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
06:46

Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic

Published on: August 25, 2016

11.5K
Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
07:31

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

Published on: May 9, 2014

12.0K

Videos de Experimentos Relacionados

Last Updated: Oct 1, 2025

Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses
11:20

Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses

Published on: July 2, 2012

15.1K
Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
06:46

Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic

Published on: August 25, 2016

11.5K
Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
07:31

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

Published on: May 9, 2014

12.0K

Área de la Ciencia:

  • * Física del plasma
  • * Física del acelerador
  • * Física de las altas energías

Sus antecedentes:

  • * Los grupos de partículas intensas que interactúan con el plasma crean poderosas estelas de plasma.
  • * Estas ondas generan campos eléctricos extremadamente altos (GV/m), superando la tecnología de radiofrecuencia convencional.
  • * La aceleración del campo de vigilia del plasma ofrece un camino hacia energías de partículas más altas en aceleradores más compactos.

Objetivo del estudio:

  • * Investigar las tasas máximas de repetición alcanzables en los aceleradores de plasma impulsados por haz.
  • * Para determinar el tiempo de recuperación del plasma después de la perturbación del campo de vigilia.
  • * Evaluar la viabilidad de las velocidades de aceleración en megahertz para aplicaciones avanzadas de aceleradores.

Principales métodos:

  • * Medición experimental del tiempo de recuperación plasmática después de la interacción con el campo de vigilia.
  • * Análisis de firmas experimentales utilizando simulaciones de canales iónicos en evolución.
  • * Caracterización de la transferencia de energía de la estela de colapso al plasma circundante.

Principales resultados:

  • * Tiempos de recuperación plasmática medidos en el rango de muchos nanosegundos.
  • * Demostrado que estos tiempos de recuperación apoyan en principio el logro de tasas de aceleración de megahertz.
  • * Se ha confirmado que las simulaciones describen con precisión los fenómenos de perturbación observados.

Conclusiones:

  • * Los tiempos de recuperación del plasma son un factor clave que limita las tasas de repetición en los aceleradores de plasma.
  • * Los tiempos de recuperación medidos a nivel de nanosegundos indican que las tasas de repetición en megahertz son alcanzables.
  • * Los módulos de campo de vigilia de plasma son prometedores como impulsores de energía de alta tasa de repetición para las instalaciones de física de partículas y ciencia fotónica.