Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

1.2K
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Atomic Nuclei: Nuclear Relaxation Processes01:23

Atomic Nuclei: Nuclear Relaxation Processes

1.1K
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis,  the precessing magnetic moments are randomly oriented around the z-axis.
1.1K
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current01:14

Diamagnetic Shielding of Nuclei: Local Diamagnetic Current

1.3K
An applied magnetic field causes the electrons present in the molecule to circulate, setting up a local diamagnetic current within the molecule. The local diamagnetic current arising from circulating sigma-bonding electrons induces a magnetic field, Blocal that opposes the applied magnetic field, B0. The effective magnetic field experienced by these nuclei is given by the difference between the applied and local magnetic fields in a phenomenon called local diamagnetic shielding. Essentially,...
1.3K
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

7.6K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
7.6K
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

870
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
870
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

427
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
427

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Multiplexed magnetic resonance imaging.

Nature·2026
Same author

Motion Correction in High-Resolution 3D Brain MRSI Without Water and Lipid Suppression.

Magnetic resonance in medicine·2025
Same author

Latent-k-space of refinement diffusion model for accelerated MRI reconstruction.

Biomedical physics & engineering express·2025
Same author

Sparse-view spectral CT reconstruction via a coupled subspace representation and score-based generative model.

Quantitative imaging in medicine and surgery·2025
Same author

One-step inverse generation network for sparse-view dual-energy CT reconstruction and material imaging.

Physics in medicine and biology·2024
Same author

Spectrum learning for super-resolution tomographic reconstruction.

Physics in medicine and biology·2024

Video Experimental Relacionado

Updated: May 4, 2026

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging
17:06

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging

Published on: November 8, 2012

26.4K

Reconstrucción de resonancia magnética dinámica de tiro cero con el modelo de difusión global a local

Yu Guan1, Kunlong Zhang2, Qi Qi2

  • 1School of Mathematics and Computer Sciences, Nanchang University, Nanchang, China.

NMR in biomedicine
|September 1, 2025
PubMed
Resumen
Este resumen es generado por máquina.

Este estudio introduce un nuevo marco de aprendizaje de tiro cero para la reconstrucción dinámica de resonancia magnética. Permite una reconstrucción precisa de imágenes a partir de datos con muestras insuficientes sin requerir conjuntos de datos de entrenamiento con muestras completas.

Palabras clave:
Modelo de difusiónResonancia magnética dinámicaEsquema de adquisición intercalada en el tiempoReconstrucción de tiro cero

Más Videos Relacionados

Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases
09:33

Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases

Published on: July 28, 2013

28.6K
Diffusion Imaging in the Rat Cervical Spinal Cord
10:46

Diffusion Imaging in the Rat Cervical Spinal Cord

Published on: April 7, 2015

11.8K

Videos de Experimentos Relacionados

Last Updated: May 4, 2026

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging
17:06

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging

Published on: November 8, 2012

26.4K
Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases
09:33

Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases

Published on: July 28, 2013

28.6K
Diffusion Imaging in the Rat Cervical Spinal Cord
10:46

Diffusion Imaging in the Rat Cervical Spinal Cord

Published on: April 7, 2015

11.8K

Área de la Ciencia:

  • Imágenes médicas
  • Inteligencia artificial
  • Modelos de difusión

Sus antecedentes:

  • Los modelos de difusión son prometedores para la reconstrucción de resonancia magnética, pero enfrentan desafíos en la resonancia magnética dinámica debido a las extensas necesidades de datos de capacitación.
  • La adquisición de datos de resonancia magnética dinámica de muestras completas es difícil debido a la complejidad espacio-temporal y los altos costos.

Objetivo del estudio:

  • Proponer un marco de aprendizaje de tiro cero para una reconstrucción dinámica precisa de la resonancia magnética a partir de datos de espacio k submuestreados.
  • Abordar las limitaciones de los métodos actuales eliminando la necesidad de datos de capacitación completamente muestreados.

Principales métodos:

  • Un esquema de adquisición intercalada en el tiempo fusiona los datos de espacio k submuestreados de cuadros adyacentes para crear datos de referencia pseudo totalmente codificados.
  • Una estrategia de refinamiento en dos etapas dentro del proceso de difusión aprende priores globales a locales para la captura efectiva de datos de distribución.
  • El marco permite la reconstrucción de tiro cero, aprendiendo directamente de los datos submuestreados.

Principales resultados:

  • El método propuesto permite una reconstrucción dinámica precisa de imágenes de resonancia magnética a partir de datos de submuestreo del espacio k.
  • Reduce efectivamente el ruido y conserva los detalles de la imagen.
  • La calidad de la reconstrucción es comparable a los enfoques de aprendizaje supervisado.

Conclusiones:

  • El marco de aprendizaje de tiro cero supera con éxito la necesidad de datos de capacitación con muestras completas en la reconstrucción dinámica de resonancia magnética.
  • El método demuestra un rendimiento robusto en la reducción del ruido y la preservación de detalles.
  • Este enfoque ofrece una solución viable para una reconstrucción dinámica de resonancia magnética eficiente y de alta calidad.