Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

Molecular Shape and Polarity03:37

Molecular Shape and Polarity

61.9K
Dipole Moment of a Molecule
61.9K
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

705
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
705
Classification of Skeletal Muscle Relaxants01:28

Classification of Skeletal Muscle Relaxants

2.7K
Skeletal muscle relaxants are a group of drugs that can reduce muscle stiffness and induce temporary paralysis to relieve pain. These agents can act centrally to reduce muscle tone or spasms in painful conditions such as multiple sclerosis (MS), amyotrophic lateral sclerosis (ALS), or spinal injuries; they are called antispasmodics or spasmolytics.
Peripherally acting skeletal muscle relaxants interfere with the neurotransmission at the neuromuscular end plate to induce paralysis during...
2.7K
Chromatographic Methods: Classification01:12

Chromatographic Methods: Classification

2.5K
Chromatographic techniques are classified in three ways: the classification is based on the physical state of the stationary and mobile phases, how the mobile phase and the stationary phase contact each other, or through the chemical or physical processes that isolate the components of the sample. Typically, the mobile phase is either a liquid or gas, while the stationary phase is either a solid or a liquid layer applied to a solid surface.
Chromatographic techniques are typically named by...
2.5K
Polymer Classification: Stereospecificity01:26

Polymer Classification: Stereospecificity

2.6K
Polymerization generates chiral centers along the entire backbone of a polymer chain. Accordingly, the stereochemistry of the substituent group has a significant effect on polymer properties. Polymers formed from monosubstituted alkene monomers feature chiral carbons at every alternate position in the polymer backbone. Relative to the predominant orientation of substituents at the adjacent chiral carbons, the polymer can exist in three different configurations: isotactic, syndiotactic, and...
2.6K
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

1.6K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.6K

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Tetrabromobisphenol S (TBBPS)-induced developmental toxicity in zebrafish embryos: impacts on cytoskeletal proteins during gastrulation.

Toxicological sciences : an official journal of the Society of Toxicology·2026
Same author

Dielectric barrier discharge ionization (DBDI) enables rapid analysis of new psychoactive substances with ion mobility-mass spectrometry.

The Analyst·2026
Same author

Photoperiod perturbations impact perfluorohexane sulfonate (PFHxS) induced developmental toxicity.

Journal of hazardous materials·2026
Same author

One-Pot Method to Access 1,3,4-Oxadiazol-2(3<i>H</i>)-ones Using Carbonyldiimidazole.

The Journal of organic chemistry·2025
Same author

SLIM Ion Mobility-Based Analysis of Low Molecular Weight Explosives.

Journal of the American Society for Mass Spectrometry·2025
Same author

Multidimensional Separations for Characterization of Isomeric PFAS Using SLIM High-Resolution Ion Mobility and Tandem Mass Spectrometry.

Analytical chemistry·2025
Same journal

Screen for Tissue-Specific Markers of Drug-Induced Phospholipidosis Using Mass Spectrometry Imaging.

Journal of the American Society for Mass Spectrometry·2026
Same journal

Molecular Framework Modification in Mass Spectrometry: Atom Exchange, Insertion, and Deletion.

Journal of the American Society for Mass Spectrometry·2026
Same journal

Interlaboratory Comparison of Orbitrap Analyzers in OrbiSIMS: Noise Parameters, Intensity Scaling, and Detection Limits.

Journal of the American Society for Mass Spectrometry·2026
Same journal

Isotope-Coded Derivatization Enables Accurate LC-MS/MS Quantification of Urinary THC-COOH without Isotope-Labeled Cannabinoid Standards.

Journal of the American Society for Mass Spectrometry·2026
Same journal

Characterization of Disulfide Bonds in Cyclic Peptides Using Electron Transfer-Ultraviolet Photodissociation Mass Spectrometry.

Journal of the American Society for Mass Spectrometry·2026
Same journal

Unveiling Ciprofloxacin Protonation Isomers: an Integrated Approach with Mass Spectrometry, Ion Mobility Spectrometry and Infrared Ion Spectroscopy.

Journal of the American Society for Mass Spectrometry·2026
Ver todos los artículos relacionados

Video Experimental Relacionado

Updated: Sep 9, 2025

High-throughput Image Analysis of Tumor Spheroids: A User-friendly Software Application to Measure the Size of Spheroids Automatically and Accurately
08:39

High-throughput Image Analysis of Tumor Spheroids: A User-friendly Software Application to Measure the Size of Spheroids Automatically and Accurately

Published on: July 8, 2014

25.4K

Perfilar múltiples subclases de esteroides habilitadas por la movilidad de iones SLIM de giro redondeado

Cole L Frank1, Breland M Jones1, Emmaleigh Efird1

  • 1Clemson University, Department of Chemistry, Clemson, South Carolina 29634, United States.

Journal of the American Society for Mass Spectrometry
|September 1, 2025
PubMed
Resumen
Este resumen es generado por máquina.

Un nuevo sistema de Estructuras para Manipulaciones de Iones sin Pérdidas (SLIM) mejora el análisis de esteroides al mejorar la transmisión de baja masa. Este avance ofrece una separación precisa de los isómeros de esteroides para diversas aplicaciones.

Palabras clave:
Espectrometría de masa y movilidad de ionesLos esteroidesEstructuras para manipulaciones de iones sin pérdidas (SLIM)

Más Videos Relacionados

Human Neuroendocrine Tumor Cell Lines as a Three-Dimensional Model for the Study of Human Neuroendocrine Tumor Therapy
12:04

Human Neuroendocrine Tumor Cell Lines as a Three-Dimensional Model for the Study of Human Neuroendocrine Tumor Therapy

Published on: August 14, 2012

29.0K
Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

4.4K

Videos de Experimentos Relacionados

Last Updated: Sep 9, 2025

High-throughput Image Analysis of Tumor Spheroids: A User-friendly Software Application to Measure the Size of Spheroids Automatically and Accurately
08:39

High-throughput Image Analysis of Tumor Spheroids: A User-friendly Software Application to Measure the Size of Spheroids Automatically and Accurately

Published on: July 8, 2014

25.4K
Human Neuroendocrine Tumor Cell Lines as a Three-Dimensional Model for the Study of Human Neuroendocrine Tumor Therapy
12:04

Human Neuroendocrine Tumor Cell Lines as a Three-Dimensional Model for the Study of Human Neuroendocrine Tumor Therapy

Published on: August 14, 2012

29.0K
Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

4.4K

Área de la Ciencia:

  • Química analítica
  • La bioquímica
  • Espectrometría

Sus antecedentes:

  • La espectrometría de masa de movilidad iónica (IM-MS) es crucial para el análisis de esteroides, ya que ofrece velocidad y separación de mezclas complejas.
  • Las técnicas de movilidad iónica de alta resolución (HRIM) se utilizan cada vez más en la esteroidómica, pero siguen siendo desafíos para los compuestos de bajo peso molecular.
  • Las estructuras para manipulaciones de iones sin pérdidas (SLIM) es una técnica emergente de HRIM con potencial para el análisis de esteroides.

Objetivo del estudio:

  • Evaluar un nuevo sistema SLIM adaptado a la baja masa para analizar varias subclases de esteroides.
  • Para evaluar el rendimiento del sistema en la separación de isómeros de esteroides difíciles.
  • Comparar la eficiencia de la nueva plataforma SLIM con los diseños tradicionales.

Principales métodos:

  • Utilizó una plataforma SLIM de baja masa con giros redondeados, gas tampón de helio y frecuencia de RF aumentada.
  • Se determinaron los valores de la sección transversal de colisión (CCS) y se compararon con las mediciones del tubo de deriva.
  • Evaluación del rendimiento de separación de los isómeros con pequeñas diferencias en la CCS.
  • Se comparó cuantitativamente el SLIM de giro redondeado con el SLIM de giro de 90° utilizando nitrógeno y helio.

Principales resultados:

  • Los valores SLIM CCS corregidos por regresión lineal mostraron una excelente concordancia con los datos del tubo de deriva, lo que pone de relieve la necesidad de factores de corrección específicos de la clase.
  • El sistema logró una buena resolución para los isómeros con ΔCCS <1%.
  • El SLIM redondeado con gas tampón de helio mejora significativamente la señal en comparación con los sistemas tradicionales y el gas tampón de nitrógeno.

Conclusiones:

  • El sistema SLIM adaptado a la masa baja demuestra una promesa significativa para el análisis rápido y específico de esteroides.
  • La plataforma SLIM optimizada mejora el análisis de esteroides de bajo peso molecular, incluidos los andrógenos anabólicos, los ácidos biliares y las hormonas.
  • Esta tecnología tiene una amplia aplicabilidad en los campos biomédico, clínico, alimentario, ambiental y antidopaje.