Jove
Visualize
Contáctanos

Videos de Conceptos Relacionados

Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

166
Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
166
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas
  1. Home
  2. Recomendaciones Para Las Directrices De Garantía De Calidad De La Radiocirugía Con Cuchillo Gamma En La República De Corea: Una Encuesta Multiinstitucional
  1. Home
  2. Recomendaciones Para Las Directrices De Garantía De Calidad De La Radiocirugía Con Cuchillo Gamma En La República De Corea: Una Encuesta Multiinstitucional

Video Experimental Relacionado

Stereotactic Radiosurgery for Gynecologic Cancer
10:35

Stereotactic Radiosurgery for Gynecologic Cancer

Published on: April 17, 2012

18.3K

Recomendaciones para las directrices de garantía de calidad de la radiocirugía con cuchillo gamma en la República de

Hyeong Cheol Moon1, Jong Hyeok Kwak2, Seong Jin Jin3

  • 1Department of Neurosurgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Cheongju, Korea.

Journal of Korean Neurosurgical Society
|September 1, 2025

Ver abstracta en PubMed

Resumen
Este resumen es generado por máquina.
Palabras clave:
Radiocirugía con cuchillo gammaEncuesta multiinstitucionalGarantía de la calidadEl TG-178

Más Videos Relacionados

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
08:25

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System

Published on: April 11, 2018

15.4K
Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
08:17

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy

Published on: June 7, 2015

15.8K

Videos de Experimentos Relacionados

Stereotactic Radiosurgery for Gynecologic Cancer
10:35

Stereotactic Radiosurgery for Gynecologic Cancer

Published on: April 17, 2012

18.3K
Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
08:25

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System

Published on: April 11, 2018

15.4K
Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
08:17

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy

Published on: June 7, 2015

15.8K

Este estudio estandarizó la garantía de calidad (QA) para la radiocirugía Leksell Gamma Knife (LGK) en Corea. Identificó las tareas diarias, mensuales y anuales esenciales de control de calidad para mejorar la seguridad del paciente y la eficacia del tratamiento.

Área de la Ciencia:

  • Física médica
  • Radiocirugía
  • Garantía de la calidad

Sus antecedentes:

  • El cuchillo gamma Leksell (LGK) es una herramienta líder en radiocirugía.
  • Las prácticas actuales de garantía de calidad (QA) de LGK en Corea carecen de estandarización.
  • La variabilidad en los protocolos de control de calidad puede afectar a la seguridad y eficacia del tratamiento.

Objetivo del estudio:

  • Identificar y estandarizar los elementos clave de control de calidad para los sistemas LGK en Corea.
  • Establecer valores nacionales de tolerancia para los protocolos de control de calidad.
  • Para comparar las prácticas coreanas de control de calidad con las directrices internacionales como TG-178.

Principales métodos:

  • Se llevó a cabo una encuesta nacional en 16 centros médicos coreanos.
  • Se evaluaron las prácticas de control de calidad de los sistemas LGK IconTM/EspritTM y PerfexionTM.
  • Las instituciones calificaron la importancia de los elementos de control de calidad (escala 0-5) para crear una lista nacional de prioridades.
  • Principales resultados:

    • Se identificaron once elementos de control de calidad diarios, seis mensuales y tres anuales de alta prioridad.
    • El control de calidad diario se centró en la radiación y la seguridad del paciente.
    • El control de calidad mensual hizo hincapié en la validación dosimétrica, y el control de calidad anual se centró en los controles mecánicos y dosimétricos.

    Conclusiones:

    • Se desarrollaron recomendaciones para la estandarización de la calidad de la radiocirugía con cuchillo gamma (GKRS) en Corea.
    • Las actualizaciones continuas de control de calidad son cruciales para los nuevos modelos LGK.
    • Los resultados apoyan el desarrollo de directrices nacionales unificadas de control de calidad para el GKRS.