Jove
Visualize
Contáctanos

Videos de Conceptos Relacionados

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

914
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
914
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

6.7K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
6.7K
Radiological Investigation II: MRI and Ventilation Perfusion Scan01:30

Radiological Investigation II: MRI and Ventilation Perfusion Scan

219
Description
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
219

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Editorial for "Mapping Neurodegenerative Changes in Clinically Uncertain Parkinsonian Syndrome Patients Using Fast Magnetic Resonance Spin TomogrAphy in Time-Domain (MR-STAT) Relaxometry at 3 T".

Journal of magnetic resonance imaging : JMRI·2026
Same author

Software-defined Radar for MRI Motion Correction: A versatile, vendor-independent Platform.

medRxiv : the preprint server for health sciences·2026
Same author

Multiparametric Free-Breathing 3D Whole-Heart Cardiac MR for Anatomical Bright- and Black-Blood Imaging With Co-Registered <math><semantics><mrow><msub><mrow><mi>T</mi></mrow> <mrow><mn>1</mn></mrow></msub> <mo>/</mo> <msub><mrow><mi>T</mi></mrow> <mrow><mn>2</mn></mrow></msub></mrow> <annotation>$$ {T}_1/{T}_2 $$</annotation></semantics></math> Myocardial Tissue Mapping at <math><semantics><mrow><mn>0</mn> <mo>.</mo> <mn>55</mn></mrow> <annotation>$$ 0.55 $$</annotation></semantics></math> T.

NMR in biomedicine·2026
Same author

Clinical Feasibility of Deep Learning Contrast Synthesis From MR Fingerprinting in Knee Osteoarthritis.

Journal of magnetic resonance imaging : JMRI·2026
Same author

3D Radial Knee Imaging at 0.55 T: Simultaneous T<sub>1</sub>-T<sub>2</sub> Mapping and Synthetic Contrast Generation in Under 4 min.

NMR in biomedicine·2026
Same author

An Open-Source Software Toolbox for Rapid Radiofrequency Coil Design and Evaluation in MRI.

Magnetic resonance in medicine·2026
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
Same journal

Evaluation of Phantom Doping Materials in Quantitative Susceptibility Mapping.

Magnetic resonance in medicine·2026
Same journal

Design of an 8-Channel Transmit 32-Channel Receive 11.7T Head Coil and Evaluation of SNR Gains.

Magnetic resonance in medicine·2026
Same journal

The Potential for Absolute Temperature Imaging Based on Brain Metabolites Using an FID-Shifting Approach in Gradient Echo Planar Spectroscopic Imaging (GREPSI).

Magnetic resonance in medicine·2026
Ver todos los artículos relacionados
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Video Experimental Relacionado

Updated: Sep 9, 2025

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

608

mtrk-Un entorno flexible para el desarrollo de secuencias de pulsos de resonancia magnética de código abierto

Anais Artiges1,2, Amanpreet Singh Saimbhi1,2, Carlos Castillo-Passi3,4,5

  • 1Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York.

Magnetic resonance in medicine
|September 2, 2025
PubMed
Resumen
Este resumen es generado por máquina.

mtrk es una nueva herramienta de código abierto que simplifica el diseño y la implementación de la secuencia de pulsos de resonancia magnética (MRI). Permite a los usuarios crear y simular secuencias fácilmente, logrando una alta similitud con las secuencias de los proveedores.

Palabras clave:
Secuencias de pulso de RMPulseq también.En el caso de lasSoftware de código abierto

Más Videos Relacionados

Neuroimaging-Guided TMS&#8211;EEG for Real-Time Cortical Network Mapping
09:55

Neuroimaging-Guided TMS–EEG for Real-Time Cortical Network Mapping

Published on: June 13, 2025

1.1K
Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.7K

Videos de Experimentos Relacionados

Last Updated: Sep 9, 2025

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

608
Neuroimaging-Guided TMS&#8211;EEG for Real-Time Cortical Network Mapping
09:55

Neuroimaging-Guided TMS–EEG for Real-Time Cortical Network Mapping

Published on: June 13, 2025

1.1K
Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.7K

Área de la Ciencia:

  • Imágenes médicas
  • Ingeniería de software
  • Imágenes por resonancia magnética

Sus antecedentes:

  • El diseño e implementación de secuencias de pulsos de resonancia magnética es complejo y requiere mucho tiempo.
  • Los métodos actuales a menudo carecen de flexibilidad y facilidad de uso, lo que dificulta el desarrollo y la difusión rápidos.

Objetivo del estudio:

  • Introducir mtrk, un marco de código abierto para el diseño, la implementación y el intercambio simplificados de secuencias de pulsos de resonancia magnética.
  • Aproveche los principios modernos de ingeniería de software para una herramienta independiente del proveedor y accesible.

Principales métodos:

  • Desarrollado mtrk con un lenguaje descriptivo legible por humanos y interfaces gráficas y Python.
  • Visualización del diagrama de secuencia de pulsos habilitada y ejecución del escáner a través de una secuencia de controladores.
  • Diseñó una secuencia de eco de espín utilizando mtrk, la convirtió en Pulseq y la comparó con las secuencias de proveedores en experimentos fantasma e in vivo.

Principales resultados:

  • mtrk y Pulseq generaron imágenes casi idénticas, mostrando más del 90% de similitud con las secuencias de los proveedores.
  • Las imágenes fantasmas de las secuencias MTRK coincidían con las imágenes sintéticas simuladas.
  • La interfaz gráfica permitió el diseño y la simulación sin conocimientos de programación.

Conclusiones:

  • mtrk simplifica el desarrollo de la secuencia de pulsos de resonancia magnética a través de un lenguaje intuitivo y la compatibilidad con Pulseq.
  • La herramienta facilita el diseño y la simulación accesibles, incluso para usuarios sin experiencia en programación.
  • mtrk promueve la creación eficiente de secuencias de pulso y el intercambio en la comunidad de resonancia magnética.