Video Experimental Relacionado
Updated: Sep 9, 2025

08:12
Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
20.0K
Medición de la variabilidad de la frecuencia cardíaca durante el embarazo utilizando tecnología de salud móvil:
Biopsychosocial science and medicine
|September 2, 2025
Resumen
El movisens EcgMove4 mide con precisión la frecuencia cardíaca (HR) y la variabilidad de la frecuencia cardíaca (HRV) en mujeres embarazadas. Este dispositivo portátil es una herramienta válida y aceptable para monitorear la fisiología del estrés durante el embarazo.
Área de la Ciencia:
- Salud mental perinatal
- Monitoreo fisiológico
- Tecnología portátil
Sus antecedentes:
- El estrés del embarazo afecta la salud de la madre y el bebé.
- Los biosensores portátiles ofrecen un monitoreo continuo y no invasivo del estrés a través de la variabilidad del ritmo cardíaco (HRV).
- La función del sistema nervioso autónomo y la regulación de las emociones son indicadores clave.
Objetivo del estudio:
- Evaluar la validez de los movisens EcgMove4 para la medición de la frecuencia cardíaca (RC) y la VRC en mujeres embarazadas.
- Evaluar la aceptabilidad del EcgMove4 en una muestra comunitaria diversa.
- Explorar la utilidad del dispositivo para la investigación de la fisiología del estrés en el embarazo.
Principales métodos:
- 101 mujeres embarazadas (segundo/tercer trimestre) participaron.
- Comparó las mediciones de EcgMove4 HR/ HRV con un monitor de electrocardiograma (ECG) tradicional.
- Evaluación de la aceptabilidad del dispositivo tras un período de uso de 10 días y entrevistas de salida.
Principales resultados:
- Se observaron altas correlaciones entre EcgMove4 y ECG para HR (r=0, 95) y HRV (RMSSD, r=0, 98).
- El dispositivo mostró una buena calidad de señal en todos los grupos raciales, pero más pobre con bandas de pecho XL.
- Los participantes informaron de una carga baja (media de 3/10) a pesar de cierta irritación de la piel (16%) y un aumento de la carga en climas cálidos.
Conclusiones:
- El EcgMove4 es una herramienta prometedora, válida y aceptable para el monitoreo de la VHC durante el embarazo.
- Las limitaciones potenciales para los tamaños de cuerpo más grandes requieren una investigación adicional.
- Permite futuras investigaciones sobre el estrés perinatal y la regulación de las emociones.
Palabras clave:
aceptabilidadpsicofisiología ambulatoriaVariabilidad del ritmo cardíacoTecnología de salud móvilembarazola validezsensores portátilesMás Videos Relacionados
Videos de Conceptos Relacionados
Holter Monitor: 24-Hour Monitoring
259
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
259
Pulse rhythm
925
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
925
Electrocardiogram
3.2K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
3.2K
Assessing Blood pressure using a doppler ultrasound
1.6K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.6K
Dysrhythmias V: Evaluating Dysrhythmias
117
Dysrhythmias, also known as arrhythmias, are disturbances in the heart's rhythm that range from benign to life-threatening. A thorough evaluation is crucial for appropriate management and involves a comprehensive medical history, physical examination, and various diagnostic tests.Medical HistorySymptoms: Collect detailed information on palpitations, dizziness, syncope, chest pain, and fatigue. Note their onset, frequency, and triggers.Previous Cardiac Issues: Document any history of heart...
117
Correlation between ECG and Cardiac Cycle
8.3K
The electrical signals recorded on an electrocardiogram (ECG) occur before the mechanical processes of contraction and relaxation during the cardiac cycle.
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
8.3K