Esta página ha sido traducida por una máquina. Otras páginas pueden seguir apareciendo en inglés. View in English

Evaluación por ultrasonido del punto de atención de la vena jugular interna durante la flexión en individuos sanos

  • 0University of Texas Southwestern Medical School Dallas, TX.

|

Resumen

No abstract available on PubMed

Videos de Conceptos Relacionados

Assessment of the Cardiovascular System III: Palpation 01:27

492

Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...

Assessing Blood pressure using a doppler ultrasound 01:19

1.6K

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

• Assemble the...

Assessment of apical radial pulse 01:25

865

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

Equipment Preparation: Gather all necessary supplies, including a watch with a second hand (for accurate counting), a stethoscope, antiseptic wipes, and a vital signs flow sheet.
Patient Interaction:

• Identification: Confirm the...

Assessment of blood pressure in brachial artery(one-step method) 01:15

689

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:

• Begin with proper hand hygiene to minimize the risk of cross-infection. This practice is essential in all healthcare procedures to ensure patient and caregiver safety.

Explain the Procedure to the Patient:

• Clearly and thoroughly explain what the patient should expect during the blood...

Assessment of radial pulse 01:11

999

Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:

Hand Hygiene:

• Begin by performing hand hygiene to prevent the transmission of microorganisms.


Preparation:

• Identification: Verify the patient's identity to ensure accurate and safe care.
• Determination:...

Assessment of apical pulse 01:17

1.2K

Assessing the Apical Pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:

• Children younger than two years.
• Cardiac patients.
• Patients before administering specific medications (e.g., cardiac glycosides like digoxin).

Location: The apical pulse is auscultated at the left midclavicular line. It is located at the 5th intercostal space, where the heart's apex is closest to the chest wall.
Preparation:

Gather...