NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

1.0K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.0K
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

4.1K
Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
4.1K
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR01:15

¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR

1.6K
The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
1.6K
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

1.4K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.4K

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

A drug-free hyaluronic acid and modified carboxymethyl cellulose double cross-linked multifunctional hydrogel wound dressing.

Journal of the mechanical behavior of biomedical materials·2026
Same author

Protonated Structure of EmrE Reveals C-terminal Tail Gating Mechanism.

bioRxiv : the preprint server for biology·2026
Same author

Nitrate-Sialin2 axis couples ER-mitochondrial calcium signaling with fatty acid metabolism to drive white adipose browning.

Nature communications·2026
Same author

ABCA8 drives bone loss via disrupting Th17/Treg imbalance: a novel immunometabolic target for osteoporosis.

Inflammation research : official journal of the European Histamine Research Society ... [et al.]·2026
Same author

Visualization of the complete preprimosome reveals the structural mechanisms governing DNA replication restart.

Nature communications·2026
Same author

Mastication Regulates Nitrate Homeostasis Through Lipid Raft-Mediated Sialin Translocation.

Oral diseases·2026
Same journal

Machine Learning-Assisted Nanopore for Enhanced Fingerprinting Analysis of Functional Glycans.

Analytical chemistry·2026
Same journal

Correction to "Maleylpyruvic Acid-Inducible Gene Expression System and Its Application for the Development of Gentisic Acid Biosensor".

Analytical chemistry·2026
Same journal

Computer-Aided Rational Hapten Design for Broad-Spectrum Monoclonal Antibody Development against Anthraquinones and Its Application in Lateral Flow Immunoassay.

Analytical chemistry·2026
Same journal

One-Step Chemoenzymatic Labeling and Oxime-Reversible Enrichment for O-GlcNAcylation Profiling under Oxidative Stress.

Analytical chemistry·2026
Same journal

Acid/NIR Dual-Responsive Nanoplatform with AND Logic-Gated Controlled Nitric Oxide Release for Companion Theranostics of Tumors.

Analytical chemistry·2026
Same journal

Multicharged Foldable Plasma Membrane Probes for Precise Cancer Cell Discrimination and Fluorescence-Guided Surgery.

Analytical chemistry·2026
Ver todos los artículos relacionados
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Video Experimental Relacionado

Updated: Jan 8, 2026

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

5.7K

Alineación Espectral de RMN Utilizando un Algoritmo de Corrección de Movimiento CryoEM

Colin A Hemme1,2, Owen A Warmuth1, Songlin Wang1

  • 1Department of Biochemistry, University of Wisconsin-Madison, 433 Babcock Dr, Madison, Wisconsin 53706, United States.

Analytical chemistry
|December 15, 2025
PubMed
Resumen
Este resumen es generado por máquina.

El software de Alineación Espectral de RMN Automatizada (ANSA) alinea espectros de RMN de estado sólido utilizando la correlación cruzada basada en imágenes. Este método supera las limitaciones de la alineación manual, mejorando el rigor de los datos y permitiendo el procesamiento automatizado para experimentos complejos.

Palabras clave:
RMN de estado sólidoAlineación espectralCorrelación cruzadaProcesamiento de datosAutomatizaciónRigor de datosBiophysicsQuímica AnalíticaBiología Estructural

Más Videos Relacionados

Single Particle Cryo-Electron Microscopy: From Sample to Structure
11:52

Single Particle Cryo-Electron Microscopy: From Sample to Structure

Published on: May 29, 2021

9.5K
Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability
06:42

Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability

Published on: September 1, 2020

3.8K

Videos de Experimentos Relacionados

Last Updated: Jan 8, 2026

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

5.7K
Single Particle Cryo-Electron Microscopy: From Sample to Structure
11:52

Single Particle Cryo-Electron Microscopy: From Sample to Structure

Published on: May 29, 2021

9.5K
Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability
06:42

Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability

Published on: September 1, 2020

3.8K

Área de la Ciencia:

  • Biofísica
  • Química Analítica
  • Biología Estructural

Sus antecedentes:

  • La RMN de estado sólido (SSNMR) de giro de ángulo mágico (MAS) ofrece alta resolución pero enfrenta desafíos de alineación espectral.
  • Los métodos existentes carecen de automatización y son subjetivos, lo que dificulta el análisis de conjuntos de datos complejos como proteínas grandes.
  • Los gradientes de campo, las variaciones de temperatura y los efectos de la secuencia de pulsos causan errores de referencia en los datos de SSNMR.

Objetivo del estudio:

  • Desarrollar un método automatizado de alineación espectral para datos de SSNMR.
  • Abordar las limitaciones de la inspección manual y subjetiva de picos para la referencia espectral.
  • Mejorar la precisión y reproducibilidad del procesamiento de datos de SSNMR.

Principales métodos:

  • Desarrollo del software Automated NMR Spectral Alignment (ANSA).
  • Adaptación de los principios de la corrección de movimiento de la criomicroscopía electrónica para espectros de RMN.
  • Utilización de funciones de correlación cruzada para tratar los espectros de RMN como imágenes para la alineación.

Principales resultados:

  • ANSA mejoró las puntuaciones de correlación cruzada de 0.33 a 1.00 en pruebas controladas.
  • Se logró una correlación de 0.96 en aplicaciones del mundo real con espectros previamente desalineados.
  • Se alinearon con éxito espectros en diversas condiciones experimentales y se corrigieron los desplazamientos en experimentos de larga duración.

Conclusiones:

  • ANSA proporciona una alineación espectral objetiva y consistente, mejorando el rigor científico.
  • El software mejora la reproducibilidad y permite la automatización de pasos críticos del procesamiento de datos de RMN.
  • ANSA está disponible como una herramienta de código abierto para su integración en los flujos de trabajo de RMN existentes.