Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

11.9K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
11.9K

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Polychromatic polarization-based shearing interferometry with channel-selective phase-gradient recovery.

Applied optics·2026
Same author

Polarizing white light interferometry for phase measurements using two simultaneous interferograms.

Applied optics·2023
Same author

Dynamic parallel phase-shifting electronic speckle pattern interferometer.

Applied optics·2020
Same author

Parallel phase shifting radial shear interferometry with complex fringes and unknown phase shift.

Applied optics·2020
Same author

Relative error in out-of-plane measurement due to the object illumination.

Applied optics·2019
Same author

Multiwavelength wavefront detection based on a lateral shear interferometer and polarization phase-shifting techniques.

Applied optics·2018

Video Experimental Relacionado

Updated: Jan 8, 2026

Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects
10:16

Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects

Published on: February 8, 2014

12.6K

Interferometría Sagnac de luz blanca de difracción de punto sin orificio para imágenes de fase dinámicas

Ana Karen Reyes, Jose Escamilla Angeles, Noel-Ivan Toto-Arellano

    Optics letters
    |December 15, 2025
    PubMed
    Resumen
    Este resumen es generado por máquina.

    Este estudio presenta un novedoso interferómetro Sagnac para imágenes de fase cuantitativa (QPI) de disparo único. El sistema logra una interferencia similar a la difracción de punto sin orificio, lo que permite la recuperación de fase de alta sensibilidad para muestras transparentes.

    Palabras clave:
    interferometría Sagnacimagen de fase cuantitativaluz blancasin orificioimagen de disparo único

    Más Videos Relacionados

    A Multimodal Wide-Field Fourier-Transform Raman Microscope
    06:46

    A Multimodal Wide-Field Fourier-Transform Raman Microscope

    Published on: December 30, 2025

    16
    Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
    10:28

    Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

    Published on: July 5, 2016

    10.7K

    Videos de Experimentos Relacionados

    Last Updated: Jan 8, 2026

    Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects
    10:16

    Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects

    Published on: February 8, 2014

    12.6K
    A Multimodal Wide-Field Fourier-Transform Raman Microscope
    06:46

    A Multimodal Wide-Field Fourier-Transform Raman Microscope

    Published on: December 30, 2025

    16
    Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
    10:28

    Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

    Published on: July 5, 2016

    10.7K

    Área de la Ciencia:

    • Óptica y Fotónica
    • Interferometría
    • Imagen de Fase

    Sus antecedentes:

    • La imagen de fase cuantitativa (QPI) es crucial para analizar muestras transparentes.
    • Los métodos tradicionales a menudo requieren orificios o configuraciones complejas, lo que limita el rendimiento y la estabilidad.
    • El desarrollo de técnicas de QPI robustas, de alta sensibilidad y de disparo único sigue siendo un área activa de investigación.

    Objetivo del estudio:

    • Presentar un novedoso interferómetro Sagnac de luz blanca de haz convergente para QPI de disparo único.
    • Lograr una interferencia similar a la difracción de punto sin orificio.
    • Demostrar una plataforma robusta y de alto rendimiento para el análisis de muestras transparentes.

    Principales métodos:

    • Se utilizó una configuración de interferómetro Sagnac de luz blanca de haz convergente.
    • Se introdujo una muestra en el plano focal para modificar asimétricamente los haces que se propagan en sentido contrario.
    • Se empleó un replicador tipo Michelson para la captura de disparo único de interferogramas desfasados utilizando un sensor CMOS a color.

    Principales resultados:

    • Se generó interferencia similar a la difracción de punto sin orificio.
    • Se logró la imagen de fase cuantitativa de disparo único con estabilidad de ruta común y compatibilidad de banda ancha.
    • Se recuperaron con éxito distribuciones de fase estáticas y dinámicas en películas delgadas, evaporación de alcohol y llamas de velas.
    • Se identificó el canal verde del sensor CMOS como el más confiable para la recuperación de fase.

    Conclusiones:

    • El interferómetro Sagnac desarrollado ofrece una plataforma robusta para QPI de disparo único y alta sensibilidad.
    • El diseño sin orificio mejora la estabilidad y el rendimiento.
    • Esta técnica es aplicable a diversas muestras transparentes, incluidos procesos dinámicos.