Jove
Visualize
Contáctanos

Videos de Conceptos Relacionados

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Boundary-aware and discrepancy-guided dynamic pseudo-labeling with consistency learning for semi-supervised 3D TOF-MRA cerebrovascular segmentation.

Physics in medicine and biology·2026
Same author

A multimodal vision-language model for generalizable annotation-free pathology localization.

Nature biomedical engineering·2026
Same author

Dynamic-Guided Diffusion Probability Model for Cranial Nerves Segmentation.

Magnetic resonance in medicine·2025
Same author

Generative Artificial Intelligence in Medical Imaging: Foundations, Progress, and Clinical Translation.

Research (Washington, D.C.)·2025
Same author

Mammo-AGE: deep learning estimation of breast age from mammograms.

Nature communications·2025
Same author

SamRobNODDI:<i>q</i>-space sampling-augmented continuous representation learning for robust and generalized NODDI.

Physics in medicine and biology·2025
Same journal

Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

Physics in medicine and biology·2026
Same journal

Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

Physics in medicine and biology·2026
Same journal

Corrigendum: Measured and Monte Carlo simulated electron backscatter to the monitor chamber for the varian TrueBeam linac (2016<i>Phys. Med. Biol</i>.<b>61</b>8779).

Physics in medicine and biology·2026
Same journal

Corrigendum: 3D range-modulator for scanned particle therapy: development, Monte Carlo simulations and experimental evaluation (2017<i>Phys. Med. Biol</i>.<b>62</b>7075).

Physics in medicine and biology·2026
Same journal

Recent progress in applications of computing to radiotherapy (ICCR 2016).

Physics in medicine and biology·2026
Same journal

Novel TMS coils designed using an inverse boundary element method.

Physics in medicine and biology·2026
Ver todos los artículos relacionados
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Video Experimental Relacionado

Updated: Jun 16, 2026

Author Spotlight: Bridging Gaps in Anatomy and Establishing a Foundation for Algorithmic Studies
04:25

Author Spotlight: Bridging Gaps in Anatomy and Establishing a Foundation for Algorithmic Studies

Published on: December 15, 2023

3.7K

Aprendizaje semisupervisado de secuencias cruzadas para la delimitación visual basada en RM multiparamétrica

Alou Diakite1, Cheng Li2, Lei Xie3

  • 1Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China, 1068 Xueyuan Avenue, Shenzhen University Town, Shenzhen, Shenzhen, Guangdong, 518055, CHINA.

Physics in medicine and biology
|December 17, 2025
PubMed
Resumen
Este resumen es generado por máquina.

Este estudio presenta un nuevo marco semisupervisado para la delimitación precisa de la vía visual (VP) utilizando RM multiparamétrica. El método modela eficazmente las complejas relaciones de los datos de RM y reduce la dependencia de los datos etiquetados para mejorar la precisión diagnóstica.

Palabras clave:
descomposición de característicasRM multiparamétricaaprendizaje semisupervisadovía visual

Más Videos Relacionados

Brain Infarct Segmentation and Registration on MRI or CT for Lesion-symptom Mapping
10:25

Brain Infarct Segmentation and Registration on MRI or CT for Lesion-symptom Mapping

Published on: September 25, 2019

49.2K
DTI of the Visual Pathway - White Matter Tracts and Cerebral Lesions
10:05

DTI of the Visual Pathway - White Matter Tracts and Cerebral Lesions

Published on: August 26, 2014

14.5K

Videos de Experimentos Relacionados

Last Updated: Jun 16, 2026

Author Spotlight: Bridging Gaps in Anatomy and Establishing a Foundation for Algorithmic Studies
04:25

Author Spotlight: Bridging Gaps in Anatomy and Establishing a Foundation for Algorithmic Studies

Published on: December 15, 2023

3.7K
Brain Infarct Segmentation and Registration on MRI or CT for Lesion-symptom Mapping
10:25

Brain Infarct Segmentation and Registration on MRI or CT for Lesion-symptom Mapping

Published on: September 25, 2019

49.2K
DTI of the Visual Pathway - White Matter Tracts and Cerebral Lesions
10:05

DTI of the Visual Pathway - White Matter Tracts and Cerebral Lesions

Published on: August 26, 2014

14.5K

Área de la Ciencia:

  • Neuroimagen
  • Análisis de imágenes médicas
  • Neurociencia computacional

Sus antecedentes:

  • La delimitación precisa de la vía visual (VP) es esencial para comprender la función del sistema visual y diagnosticar patologías relacionadas.
  • Los datos de RM multiparamétrica ofrecen información rica pero presentan desafíos en el modelado de relaciones entre secuencias y requieren datos etiquetados extensos para el entrenamiento.
  • Los métodos existentes luchan por integrar eficazmente la información complementaria de diversas secuencias de RM y están limitados por la necesidad de grandes conjuntos de datos anotados.

Objetivo del estudio:

  • Desarrollar un marco semisupervisado novedoso para la delimitación precisa de la vía visual (VP) que supere las limitaciones de los métodos existentes.
  • Modelar eficazmente las complejas relaciones entre secuencias dentro de los datos de RM multiparamétrica.
  • Abordar el desafío de la limitada cantidad de datos de entrenamiento etiquetados en tareas de segmentación de imágenes médicas.

Principales métodos:

  • Un marco de descomposición de características multiparamétricas semisupervisado que integra un módulo de descomposición de características con restricción de correlación (CFD).
  • El módulo CFD captura las características únicas de la secuencia de RM y facilita la fusión de información.
  • Un módulo de mejora de muestras basado en la consistencia (CSE) aprovecha los datos no etiquetados para generar y reforzar la información de los bordes, mitigando la necesidad de etiquetas extensas.

Principales resultados:

  • El marco propuesto se validó en dos conjuntos de datos públicos y un conjunto de datos de RM de difusión multiescala (MDM) interno.
  • Los resultados experimentales demostraron un rendimiento de delimitación superior en comparación con seis enfoques de vanguardia.
  • El marco manejó eficazmente las complejas relaciones entre secuencias y los escenarios con datos etiquetados limitados.

Conclusiones:

  • El marco desarrollado proporciona una solución robusta para la delimitación precisa de la vía visual (VP), abordando los desafíos clave en el análisis de RM multiparamétrica.
  • Este enfoque mejora la comprensión del sistema visual humano.
  • El método tiene un potencial significativo para mejorar el diagnóstico de trastornos relacionados con la vía visual.