Jove
Visualize
Contáctanos

Videos de Conceptos Relacionados

Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

19.9K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
19.9K
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

12.1K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.1K

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

COX-2 inhibition improves immune system homeostasis and decreases liver damage in septic rats.

The Journal of surgical research·2009
Same author

Mass spectral characterization of organophosphate-labeled, tyrosine-containing peptides: characteristic mass fragments and a new binding motif for organophosphates.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences·2009
Same author

3D-SURFER: software for high-throughput protein surface comparison and analysis.

Bioinformatics (Oxford, England)·2009
Same author

Total arch replacement with stented elephant trunk technique: a proposed treatment for complicated Stanford type B aortic dissection.

Journal of cardiac surgery·2009
Same author

Top-emitting white organic light-emitting devices with a one-dimensional metallic-dielectric photonic crystal anode.

Optics letters·2009
Same author

[Detection of tick and tick-borne pathogen in some ports of Inner Mongolia].

Zhonghua liu xing bing xue za zhi = Zhonghua liuxingbingxue zazhi·2009
Same journal

Denoising algorithm of Φ-OTDR systems based on adaptive fractional wavelet transform denoising.

Optics express·2026
Same journal

Millisecond photon-to-photon latency and high-speed volumetric projection system for optogenetics.

Optics express·2026
Same journal

Polarization-encoded coaxial structured light for high-precision 3D surface profilometry.

Optics express·2026
Same journal

Discrete freeform optical design based on collaborative optimization of point cloud and local normals.

Optics express·2026
Same journal

Ultrafast ghost imaging with 25 GHz speckle switching and wavelength-division multiplexing.

Optics express·2026
Same journal

Atomic vapor cells fabricated by femtosecond laser welding of standard-optical-quality glass.

Optics express·2026
Ver todos los artículos relacionados
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Video Experimental Relacionado

Updated: Jan 8, 2026

Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection
12:57

Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection

Published on: October 13, 2017

9.5K

Estándar de punto cuántico único para la eficiencia de detección confocal

Bin Li, Xiaopeng Chen, Guofa Qu

    Optics express
    |December 19, 2025
    PubMed
    Resumen
    Este resumen es generado por máquina.

    Desarrollamos un método rápido y cuantitativo que utiliza puntos cuánticos únicos para medir la eficiencia de detección del microscopio confocal. Esta técnica determina con precisión la eficiencia analizando los tiempos de llegada de los fotones, lo que simplifica la evaluación del rendimiento.

    Palabras clave:
    punto cuánticomicroscopio confocaleficiencia de detecciónimagen cuantitativaóptica cuántica

    Más Videos Relacionados

    Compact Quantum Dots for Single-molecule Imaging
    17:14

    Compact Quantum Dots for Single-molecule Imaging

    Published on: October 9, 2012

    18.6K
    Video-rate Scanning Confocal Microscopy and Microendoscopy
    14:10

    Video-rate Scanning Confocal Microscopy and Microendoscopy

    Published on: October 20, 2011

    28.5K

    Videos de Experimentos Relacionados

    Last Updated: Jan 8, 2026

    Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection
    12:57

    Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection

    Published on: October 13, 2017

    9.5K
    Compact Quantum Dots for Single-molecule Imaging
    17:14

    Compact Quantum Dots for Single-molecule Imaging

    Published on: October 9, 2012

    18.6K
    Video-rate Scanning Confocal Microscopy and Microendoscopy
    14:10

    Video-rate Scanning Confocal Microscopy and Microendoscopy

    Published on: October 20, 2011

    28.5K

    Área de la Ciencia:

    • Microscopía óptica
    • Óptica cuántica
    • Nanotecnología

    Sus antecedentes:

    • La medición precisa de la eficiencia de detección del microscopio confocal es vital para la evaluación del rendimiento, pero es técnicamente desafiante.
    • Los métodos existentes pueden consumir mucho tiempo o requerir procedimientos de calibración complejos.
    • La imagen cuantitativa de fluorescencia y la microscopía de superresolución dependen de valores precisos de eficiencia de detección.

    Objetivo del estudio:

    • Presentar un método rápido y cuantitativo para medir la eficiencia de detección del microscopio confocal.
    • Establecer un punto de referencia conveniente para la optimización rutinaria del microscopio y las comparaciones entre laboratorios.
    • Facilitar los avances en la imagen cuantitativa de fluorescencia.

    Principales métodos:

    • Utilización de la fotoluminiscencia de un único punto cuántico como fuente de luz.
    • Análisis de la autocorrelación de los tiempos de llegada de fotones de los estados de un solo excitón y de excitones dobles.
    • Implementación de un método que requiere menos de 30 segundos para la medición.

    Principales resultados:

    • Determinación precisa de la eficiencia de detección del microscopio confocal.
    • El método demuestra alta tolerancia a las variaciones en la potencia del láser.
    • No se necesitan procedimientos de calibración para esta técnica.
    • Las mediciones se completan en menos de 30 segundos.

    Conclusiones:

    • El método del punto cuántico único ofrece un enfoque rápido, cuantitativo y sin calibración para medir la eficiencia de detección.
    • Esta técnica sirve como una herramienta valiosa para la optimización rutinaria del microscopio y las comparaciones fiables.