Eficacia del ácido peracético y el cloro en el manejo de biopelículas de Salmonella en sistemas de bucle de riego
Video Experimental Relacionado
Updated: Jan 8, 2026

Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
Rawane Raad1, Blanca Ruiz-Llacsahuanga1, Charles Bency Appolon1
1Department of Food Science and Technology, University of Georgia, Athens, Georgia, USA.
Abstract:
Biofouling presents significant challenges to the crop production industry, notably reducing irrigation efficiency and potentially dispersing pathogens to irrigated crops. This study evaluated the efficacy of peracetic acid (PAA) and chlorine (Cl) against Salmonella biofilms in irrigation lines with or without fertilizers. Pond water (PW) with 2-4-1 fish emulsion (O), PW with 4-0-8 synthetic liquid fertilizer (S), or PW with no fertilizer (NoFert) was inoculated with 2 log CFU/mL of a rifampicin-resistant Salmonella cocktail. Inoculated water was then circulated through polyethylene loop irrigation system for a month. Salmonella populations both in the water and attached to the tubing were determined. Data showed that a single point of contamination from the water resulted in a biofilm formation with O and NoFert, but not the S treatments, after 3 days. Both PAA and Cl effectively reduced Salmonella populations for all fertilizer treatments in water samples. However, when no sanitizer was introduced to the line, bacterial dispersion resulted in the contamination of a subsequent irrigation event for the O treatments but not the S and NoFert treatments, which presented no microbial proliferation. Our findings suggest that O treatments resulted in persistent biofilm formation that could lead to contamination of irrigation water when no sanitizers are introduced. These studies provide insight into the behavior of foodborne pathogens in irrigation distribution systems.IMPORTANCEThe accumulation of bacteria in water distribution systems due to biofouling can lead to contamination, making it crucial to evaluate and implement effective mitigation measures to prevent these issues and ensure safe and efficient irrigation practices. The use of the 2-4-1 fish emulsion in-line may support the establishment of Salmonella biofilms and subsequent cross-contamination of irrigation water if not fully flushed from the system. This study demonstrates that PAA and Cl effectively reduce Salmonella contamination in water but will not eliminate populations in-line once biofilms are established.
Más Videos Relacionados
07:07Controlled-release of Chlorine Dioxide in a Perforated Packaging System to Extend the Storage Life and Improve the Safety of Grape Tomatoes
Published on: April 7, 2017
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Videos de Conceptos Relacionados
Chemical Agents for Microbial Control
Hand hygiene
Hand washing...
Biological Methods for Microbial Control
Antimicrobial Effectiveness
Physical Methods for Controlling Microbial Growth: Radiation and Filtration