Jove
Visualize
Contáctanos

Videos de Conceptos Relacionados

Divergence and Curl of Magnetic Field01:26

Divergence and Curl of Magnetic Field

3.9K
The magnetic field due to a volume current distribution given by the Biot–Savart Law can be expressed as follows:
3.9K
Elastic Strain Energy for Shearing Stresses01:20

Elastic Strain Energy for Shearing Stresses

461
As discussed in previous lessons, strain energy in a material is the energy stored when it is elastically deformed, a concept crucial in materials science and mechanical engineering. This energy results from the internal work done against the cohesive forces within the material. When a material undergoes shearing stress and corresponding shearing strain, the strain energy density, which is the energy stored per unit volume, is calculated. Within the elastic limit, where the stress is...
461
Magnetic Susceptibility and Permeability01:31

Magnetic Susceptibility and Permeability

2.2K
In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
2.2K
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

8.9K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
8.9K
Magnetostatic Boundary Conditions01:28

Magnetostatic Boundary Conditions

1.6K
An electric field suffers a discontinuity at a surface charge. Similarly, a magnetic field is discontinuous at a surface current. The perpendicular component of a magnetic field is continuous across the interface of two magnetic mediums. In contrast, its parallel component, perpendicular to the current, is discontinuous by the amount equal to the product of the vacuum permeability and the surface current. Like the scalar potential in electrostatics, the vector potential is also continuous...
1.6K
Dynamic Modulus of Elasticity of Concrete01:16

Dynamic Modulus of Elasticity of Concrete

900
The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
900

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Feasibility of real-time in-magnet exercise cardiovascular MRI with an individualized exercise protocol: Quantitative assessment at low, intermediate, and high exercise intensities.

Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance·2026
Same author

Deep learning-driven inversion framework for shear modulus estimation in magnetic resonance elastography.

Magma (New York, N.Y.)·2026
Same author

Machine Learning Enhanced Quantum-Safe Encryption: A Novel Optimisation Framework.

Sensors (Basel, Switzerland)·2026
Same author

Green extraction and phenolic profiling of bitter melon (<i>Momordica charantia</i>) using UHPLC-DAD analysis: unveiling its antidiabetic and anticancer potential.

Frontiers in nutrition·2026
Same author

EMORe: Motion-Robust 5D MRI Reconstruction via Expectation-Maximization-Guided Binning Correction and Outlier Rejection.

IEEE transactions on medical imaging·2026
Same author

Enzymes-assisted green ultrasonic extraction with UPLC-DAD quantification of phenolic compounds in chia seeds with a comparative evaluation based on geographical origins.

Ultrasonics sonochemistry·2026
Same journal

Poisoning the Genome: Targeted Backdoor Attacks on DNA Foundation Models.

ArXiv·2026
Same journal

Mechanistic mathematical model of the in vitro infection dynamics of Bunyamwera and Batai viruses including MOI-dependent shortening of the eclipse phase.

ArXiv·2026
Same journal

AI-Driven Lumped-Element Modeling of Human Respiratory System for Studying Voice Mechanics.

ArXiv·2026
Same journal

Beyond Algorithms: Conceptual Innovation in Medical Imaging AI.

ArXiv·2026
Same journal

Feynman Kac Reweighted Schrödinger Bridge Matching for Surface-Based Tau PET Harmonization.

ArXiv·2026
Same journal

Agentic Discovery of Non-Canonical Antimicrobial Peptides with AMPGAN v3.

ArXiv·2026
Ver todos los artículos relacionados
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Video Experimental Relacionado

Updated: Jan 7, 2026

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
12:18

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth

Published on: February 9, 2012

12.8K

Marco de Inversión Impulsado por Aprendizaje Profundo para la Estimación del Módulo de Corte en Elastografía por

Hassan Iftikhar1,2, Rizwan Ahmad1,3, Arunark Kolipaka1,2,3

  • 1Biomedical Engineering, The Ohio State University, Columbus, Ohio, USA.

ArXiv
|December 25, 2025
PubMed
Resumen
Este resumen es generado por máquina.

Un nuevo método de aprendizaje profundo, DIME, mejora la estimación de la rigidez de la Elastografía por Resonancia Magnética (MRE) superando las limitaciones del algoritmo tradicional de Inversión Directa Multimodal (MMDI). DIME ofrece un mapeo de rigidez tisular más preciso y robusto para aplicaciones clínicas.

Palabras clave:
Elastografía por Resonancia MagnéticaMódulo de corteAprendizaje profundoEstimación de rigidezInversión directa multimodal

Más Videos Relacionados

Viscoelastic Characterization of Soft Tissue-Mimicking Gelatin Phantoms using Indentation and Magnetic Resonance Elastography
07:57

Viscoelastic Characterization of Soft Tissue-Mimicking Gelatin Phantoms using Indentation and Magnetic Resonance Elastography

Published on: May 10, 2022

2.5K
Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
06:09

Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI

Published on: July 21, 2023

1.8K

Videos de Experimentos Relacionados

Last Updated: Jan 7, 2026

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
12:18

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth

Published on: February 9, 2012

12.8K
Viscoelastic Characterization of Soft Tissue-Mimicking Gelatin Phantoms using Indentation and Magnetic Resonance Elastography
07:57

Viscoelastic Characterization of Soft Tissue-Mimicking Gelatin Phantoms using Indentation and Magnetic Resonance Elastography

Published on: May 10, 2022

2.5K
Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
06:09

Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI

Published on: July 21, 2023

1.8K

Área de la Ciencia:

  • Ingeniería Biomédica
  • Imágenes Médicas
  • Aprendizaje Automático

Sus antecedentes:

  • La Elastografía por Resonancia Magnética (MRE) estima la rigidez al corte del tejido utilizando algoritmos de inversión como la Inversión Directa Multimodal (MMDI).
  • La dependencia de MMDI de la ecuación de Helmholtz y el operador Laplaciano lo hace sensible al ruido y a las suposiciones de medios uniformes, lo que limita la precisión.
  • La estimación de rigidez robusta y precisa es crucial para diagnosticar afecciones como la fibrosis hepática.

Objetivo del estudio:

  • Introducir y validar el Marco de Inversión Impulsado por Aprendizaje Profundo para la Estimación del Módulo de Corte en MRE (DIME).
  • Mejorar la robustez y precisión de la estimación de rigidez de MRE en comparación con el algoritmo convencional MMDI.
  • Evaluar el rendimiento de DIME en datos de MRE simulados e in vivo.

Principales métodos:

  • DIME se entrenó con campos de desplazamiento y mapas de rigidez generados mediante simulaciones de Modelado de Elementos Finitos (FEM) utilizando pequeños parches de imagen.
  • El algoritmo se validó en conjuntos de datos de MRE hepática simulados homogéneos, heterogéneos e informados por la anatomía.
  • El rendimiento de DIME se evaluó además utilizando datos de MRE in vivo de sujetos sanos y con fibrosis.

Principales resultados:

  • En simulaciones, DIME produjo mapas de rigidez con baja variabilidad, límites precisos y alta correlación con la verdad fundamental, superando a MMDI.
  • DIME reprodujo con precisión los patrones de rigidez de la verdad fundamental en MRE simulada del hígado (r = 0.99, R² = 0.98), mientras que MMDI subestimó la rigidez.
  • In vivo, DIME mostró una mayor correlación con la verdad fundamental y conservó los patrones fisiológicos, a diferencia de MMDI que exhibió un sesgo direccional.

Conclusiones:

  • DIME demuestra una robustez y precisión superiores en la estimación de rigidez de MRE en comparación con MMDI.
  • El enfoque de aprendizaje profundo aborda eficazmente las limitaciones de MMDI relacionadas con la sensibilidad al ruido y las suposiciones del medio.
  • DIME muestra un potencial significativo para aplicaciones clínicas fiables en la caracterización de tejidos basada en MRE.