Factores que influyen en la titulación de lesiones en un catéter de punto de ablación de campo pulsado monopolar: un
Arwa Younis1, Joe Demian1, Savannah Bifulco2
1Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, OH (A.Y., J.D., I.L., P.S., A.A.H., M.M., T.T., C.T., H.N., M.F., W.S., M.K., O.W.).
Background:
Despite the rise of pulsed-field ablation (PFA), predicting and titrating lesion geometry remains challenging. This study aimed to find modifiable parameters that can accurately and repeatedly predict focal PFA lesions across a range of dimensions and to develop a model to predict lesion geometry.
Methods:
An in vivo study was performed in 9 swine using an investigational dual-energy contact-force focal catheter with local impedance. Ablations were performed endocardially in the right and left ventricles using settings specifically selected to provide a wide range of lesion dimensions. Predefined PFA applications (1, 2, or 4) were delivered while maintaining different contact-force values (5-45 g). Four different voltages were used (1.0, 1.4, 2.0, and 2.2 kV). Following a 1-week survival period, the animals were euthanized for histopathologic examination.
Results:
In the study characterization data set, a total of 78 PFA lesions were analyzed. Lesion depth ranged from 1.4 mm to 12.3 mm, while lesion width ranged from 3.3 mm to 21.2 mm. All 3 tested parameters-contact force, number of applications, and voltage-demonstrated a positive linear correlation with lesion depth (P<0.01). The proposed formula (Focal FARAPULSE Index Model) showed a strong positive correlation with lesion depth (R=0.83; P<0.0001) and lesion width (R=0.76; P<0.0001). A perpendicular catheter orientation was correlated with deeper lesions than a parallel orientation. No ST-segment elevations or sustained ventricular arrhythmias were observed.
Conclusions:
Our findings demonstrate that PFA can be effectively titrated and predicted using the Focal FARAPULSE Index Model to create lesions of varying depths (1-12 mm), with these results being specific to the proprietary waveform and catheter used.
Más Videos Relacionados
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Videos de Conceptos Relacionados
Factors Affecting Protein-Drug Binding: Patient-Related Factors
Age stands as a key determinant in protein-drug binding. Neonates, characterized by low albumin content, experience heightened concentrations of unbound drugs such as phenytoin and...
Therapeutic Drug Monitoring: Affecting Factors
Effect of Hepatic Disease on Pharmacokinetics: Drug Dosing and Hepatic Blood Flow
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Effect of Hepatic Disease on Pharmacokinetics: Dose Adjustments Due to Hepatic Impairment
Impact of Pharmacokinetic–Pharmacodynamic Models: Regulatory Decisions